110
nEG
negative half-wave
Unit
-
Setting range
tri / Sin / rEc / OFF
Factory setting
OFF
tri
Triangular waveform
Sin
Sine ... sinusoidal waveform (standard setting for a low-noise,
stable arc)
rEc
Rectangular waveform with decreased edge steepness, for re
-
ducing noise levels compared to those that occur with the 100%
rectangular waveform
OFF
100% rectangular waveform (stable but loud arc)
PhA
Phase adjustment of the mains connection of two power sources for simultaneous AC
welding.
Unit
-
Setting range
0 - 5
Factory setting
0
IMPORTANT!
Before phase adjustment the "ACF" parameter must be set to "Syn" in the
AC/polarity reversal set-up menu.
Phase adjustment takes place as follows:
-
Prepare a test workpiece for simultaneous AC welding.
-
Adjust the PhA value on a power source to between 0 and 5 until the best welding
result is achieved.