126
dSP | Exx
Cause:
Fault in the central control and regulation unit
Remedy:
Contact After-Sales Service
dSP | Sy
Cause:
Fault in the central control and regulation unit
Remedy:
Contact After-Sales Service
dSP | nSy
Cause:
Fault in the central control and regulation unit
Remedy:
Contact After-Sales Service
r | E30
Cause:
r-calibration: there is no contact with the workpiece
Remedy:
Connect up the grounding (earthing) cable; ensure a tight connection be
-
tween the electrode and the workpiece
r | E31
Cause:
r-calibration: procedure has been interrupted by repeated pressing of the
torch trigger or Gas test button.
Remedy:
Ensure a tight connection between the electrode and the workpiece
press the torch trigger or Gas test button once only
r | E33
Cause:
r-calibration: poor contact between the tungsten electrode and the workpiece
Remedy:
Clean the point of contact, check the earthing (grounding) connection
r | E34
Cause:
r-calibration: poor contact between the tungsten electrode and the workpiece
Remedy:
Clean the point of contact, check the earthing (grounding) connection
no | Arc
Cause:
Arc break
Remedy:
Press the torch trigger repeatedly; clean the surface of the workpiece
no | H2O
Cause:
Cooling unit flow watchdog has been triggered
Remedy:
Check the cooling unit; if necessary, top up the coolant or bleed the system
as described in "Putting the cooling unit into service"
hot | H2O
Cause:
Thermostat on cooling unit has tripped
Remedy:
Wait until the end of the cooling phase, i.e. until "Hot | H2O" is no longer dis
-
played.
ROB 5000 or field bus coupler for robot control: Before resuming welding, in
-
itialise the "Source error reset" signal.
-St | oP-
If the power source is being used with a robot interface or a field bus
Cause:
Robot not ready
Remedy:
Initialise "Robot ready" signal, initialise "Source error reset" signal (N.B.
"Source error reset" only available in conjunction with ROB 5000 and field bus
coupler for robot control)
Содержание MagicWave 1700 Job
Страница 2: ...2...
Страница 18: ...18...
Страница 19: ...General information...
Страница 20: ......
Страница 25: ...Control elements and connections...
Страница 26: ......
Страница 46: ...46...
Страница 47: ...Installation and commissioning...
Страница 48: ......
Страница 57: ...Welding...
Страница 58: ......
Страница 66: ...66 Special 4 step mode variant 6 0 5 s 0 5 s 0 5 s 0 5 s GPr tdown G L G H tup I t I1 IS IE I1 I1 I2 0 5 s...
Страница 86: ...86...
Страница 87: ...Setup settings...
Страница 88: ......
Страница 121: ...Troubleshooting and maintenance...
Страница 122: ......
Страница 131: ...Appendix...
Страница 132: ......
Страница 146: ...146...
Страница 147: ...147 EN...