Power source does not function
Mains switch is on, but indicators are not lit up
Cause:
There is a break in the mains lead; the mains plug is not plugged in
Remedy:
Check the mains lead, ensure that the mains plug is plugged in
Cause:
Mains socket or mains plug faulty
Remedy:
Replace faulty parts
Cause:
Mains fuse protection
Remedy:
Change the mains fuse protection
No welding current
Mains switch is ON, overtemperature indicator is lit up
Cause:
Overload
Remedy:
Check duty cycle
Cause:
Thermostatic safety cut-out has tripped
Remedy:
Wait until the power source automatically comes back on after the end of the
cooling phase
Cause:
The fan in the power source is faulty
Remedy:
Contact After-Sales Service
No welding current
Mains switch is on, indicators are lit up
Cause:
Grounding (earthing) connection is incorrect
Remedy:
Check the grounding (earthing) connection and terminal for correct polarity
Cause:
There is a break in the current cable in the welding torch
Remedy:
Replace welding torch
Nothing happens when the torch trigger is pressed
Mains switch is on, indicators are lit up
Cause:
The control plug is not plugged in
Remedy:
Plug in the control plug
Cause:
Welding torch or welding torch control line is faulty
Remedy:
Replace welding torch
Содержание MagicWave 1700 Job
Страница 2: ...2...
Страница 18: ...18...
Страница 19: ...General information...
Страница 20: ......
Страница 25: ...Control elements and connections...
Страница 26: ......
Страница 46: ...46...
Страница 47: ...Installation and commissioning...
Страница 48: ......
Страница 57: ...Welding...
Страница 58: ......
Страница 66: ...66 Special 4 step mode variant 6 0 5 s 0 5 s 0 5 s 0 5 s GPr tdown G L G H tup I t I1 IS IE I1 I1 I2 0 5 s...
Страница 86: ...86...
Страница 87: ...Setup settings...
Страница 88: ......
Страница 121: ...Troubleshooting and maintenance...
Страница 122: ......
Страница 131: ...Appendix...
Страница 132: ......
Страница 146: ...146...
Страница 147: ...147 EN...