3.2.7 Loading fuel in a store space with a horizontal screw discharge unit
❒ When the boiler system is running, fuel can be tipped into the store at any time.
➥ CAUTION: fuel may only be blown in if the pressure conditions in the store are
suitable and the water content of the fuel does not exceed a maximum of W30.
3.2.8 Loading fuel in a store space with an inclined screw discharge unit
The inclined screw must always be moved into an upright position in order to fill the
store.
This can be done as follows:
❒ If the store is filled while the boiler system is running, the screw moves
automatically into an upright position.
➥ If the store is empty, the screw must be moved by hand into an upright position
and wedged with fuel.
❒ If the feed system is not running when the store is filled, the screw can be held
upright using string.
➥ TIP: the string should be thin enough for it to break as the store is filled.