4 | Technical information
18
M1820921_en | Installation instructions Dual fuel boiler SP Dual compact
4 Technical information
4.1 Dimensions SP Dual compact
H1
H3
H8
H2
H6
H7
H5
H4
B2
B3
B4
B5
B8
B9
B10
B6
B7
B1
L2
L3
L1
Dimensi
on
Description
Unit
15-20
L1
Length, pellet unit
mm
855
L2
Length, firewood boiler
1000
L3
Total length incl. induced draught fan
1080
B1
Total width including WOS lever
1145
B2
Width, firewood boiler
685
B3
Width, pellet unit
315
B4
SP Dual width
1000
B5
Distance between flue gas pipe connection and side of boiler
665
B6
Distance between safety heat exchanger connection and side of boiler
430
B7
Distance between safety heat exchanger connections
65
B8
Distance between flow connection and side of boiler
570
B9
Distance between return connection and side of boiler
150
B10
Distance between drainage connection and side of boiler
890
H1
Height, pellet unit
1340
H2
Height of flue gas pipe connection
1)
1300
H3
Total height incl. flue gas nozzle
1395
H4
Height of hose line connection
1255
H5
Height, safety heat exchanger connection
1040
H6
Height, drainage connection
150
H7
Height, flow connection
1055
1. When using the optional flue pipe nozzle for low chimney connections