6 | Installation
46
M1820921_en | Installation instructions Dual fuel boiler SP Dual compact
6.6.6 Installing the insulated door
Installation of the insulated door is explained below using the example of the door stop on
the left. To mount the insulated door with the door stop on the right, invert and follow the
same steps!
r
Mount counter plate for magnetic latches on the side panel on the opposite side of the
door stop
Ä
NOTE
: counter plate may already be mounted on one side
r
Hang the insulated door at the bottom onto the half-length taper grooved pin and
secure at the top with a door pin
r
When insulated door is closed:
Measure the distance to the left and right between the insulated door and the control
Ä
The two distances must be equal!
Ä
If necessary adjust the side panels at the brackets
r
When the positioning is correct, tighten the screws in the brackets
r
Close the round cutouts in the front cover plate using plastic plugs