Service-Manual_artista_630_640_english_V4.01_032069_50_04.doc
94
5h BSR foot update:
What to adjust:
•
Attach BSR foot.
•
Connect BERNINA USB data stick containing latest update file.
•
Press icon h to start updating process.
•
Follow the instructions on the screen.
5i Resetting artista 640 upper thread tension to default
What to adjust:
•
Press OK icon to reset to electronic upper thread tension default.
•
Do you really want to reset?
appears before final confirmation.
•
Press OK icon again to reset to default. This brings you back to
menu 5.
5j Resetting to factory settings (Reset All):
What to adjust:
•
Press OK icon to reset to factory settings.
•
Do you really want to reset?
appears before final confirmation.
•
Press OK icon again to reset to default. This brings you back to
menu 5.
Note:
•
It is essential to save the customer’s data on a BERNINA USB data stick before resetting to
factory settings!
•
See data saving in service program, test 1g.