Service-Manual_artista_630_640_english_V4.01_032069_50_04.doc
56
64
67
5.18 artista 630 needle height
Standard:
•
Set needle to right needle position.
•
Set hook tip flush with right hand needle edge
•
needle on its upwards movement).
•
From a front view, the lower edge of the hook tip
should be 0.2mm above the top edge of the
needle eye.
Correction:
•
Loosen needle bar clamp screw (
64
).
•
Move needle bar to prescribed position.
•
Retighten screw (
64
).
Attention:
•
The needle bar must not turn.
•
Use twin needles to check if necessary.
Note:
•
Check threader position (
p. 56
).
5.19 artista 640 needle height
Standard:
•
Attach 9mm presser foot and set needle to left position.Position hook
tip flush with the left edge of the needle (needle must be in its upwards
movement).
•
From a front view, the point of the hook tip should be 0.2mm below the
upper edge of the needle eye.
Correction:
•
Remove needle, thread guide clamp and
thread guide.
•
It may be necessary to replace the stop pin.
008211 5000 = ø 1.50mm
008211 5001 = ø 1.85mm
008211 5002 = ø 2.20mm
008211 5003 = ø 2.55mm
008211 5004 = ø 2.90mm
0.2 mm