FR150A Series Multifunctional Compact
Inverter
- 28 -
the current frequency)
28: Swing frequency reset(output
the central frequency)
29: Run command switched to
keypad control
30: Run command switched to
terminal control
31: Run command switched to
communication control
32: Count input
33: Count clear
34: Length count
35: Length clear
36: DC brake input command at
Stop
37: Speed/torque control switch
38: Disable Reverse
39: Disable Forward
50: Enable Special purpose
machine function
F04.10
Filtering time of digital
input terminalD11~D17
0.000
~
1.000s
0.010s
△
F04.11
Delay time before
DI1 is valid
0.0
~
300.0s
0.0s
△
F04.12
Delay time before
DI2 is valid
0.0
~
300.0s
0.0s
△
F04.13
Terminal DI1
~
DI4
positive/negative logic
DI4
、
DI3
、
DI2
、
DI1
0000
×
0: Positive logic(Terminals are on at
0V/off at 24V)
1: Negative Logic (Terminals are off
at 0V/on at 24V)
F04.14
Terminal
DI7positive/negative logic
Reserved DI7
00
×
0: Positive logic
1: Negative Logic
F04.15
FWD/REV terminal
control mode
0: Two-wire mode 1
0
×
1: Two-wire mode 2
2: Three-wire mode 1
3: Three-wire mode 2
4: Pulse operation stop
F04.16
Terminal UP/DOWN
frequency adjustment
control
Unit's place: action when stop
0: Clear
1: Holding
00001
×
Ten
’s place: action on power loss
0: Clear
1: Holding
Hundreds place: integral function
0: No integral function
1: Integral function enabled
Thousand’s place: Select if it can
be reduced to negative frequency
0: Disable
1: Enable
Ten t
housand’s place: Select if
JOG can clear UP/DOWN
0: Not zero-clear
1: Zero-clear
F04.17
Terminal UP/DOWN
0.00
~
50.00Hz 0.00:Disabled
1.00Hz/
△