F3D3
Series
Service Manual Factory Level 3 Parameter Access / 1.11A
Questions? Call Franke Technical Support Group For Your Area. Copyright
2012 Franke, Inc. All rights reserved.
Factory Level 3 - Parameter Guide – Page 1
[For Latest Models with BL 2.00; APP 2.12a Chip Software
1)
]
Parameter
Range
Unit
3)
Factory
Default
Notes
Country Exceptions
GM Exceptions
No.
Name
Low High
US EU JP LA CN AP
EU-B
US-
GM
CAN-
GM
Other
-GM
EU-Y
P01
Language
1
5
1
1=English, 2=Deutsch,
3=Espanola, 4=Francais,
5=French/English (Canada)
1
1
1
1
5
1
1
1
5
1
1
P02
Set Point
-50
20
Deg F
-5
Temperature set point
P03
Offset
-30
30
Deg F
8
Temperature offset from sensor
P04
High Alarm Set
Point
-100
50
Deg F
40
Temperature that triggers a high
alarm (LON Models only)
P05
High Alarm (Start
Up) Delay
1
300
(M)
minutes
100
Time to wait after high alarm
signal, until message appears
P06
High Alarm Dwell
1
300
(M)
minutes
60
Temperature must remain (dwell)
for this time
P07
Hysteresis
0.5
5
Deg F
1.0
Used in temperature control
P09
Compressor Off
Time
1
200
(S)
seconds
120
Minimum time the compressor
must be off before restarting.
P10
Down Shift LM
1
19
20=off
(M)
minutes
4
Time for a size downshift from
large to medium. 20 = Off
4
7
4
4
4
4
Off
Off
Off
Off
10
P11
Down Shift M1S
1
19
(20= off)
(M )
minutes
20 (off)
Time for an initial size downshift
from medium to small. 20 = Off
Off 3 Off
Off
Off
Off
Off
Off
Off
Off
5
P12
Down Shift M2S
1
19
(20= off)
(M)
minutes
20 (off)
Time for subsequent size
downshift from medium to small.
20 = Off
Off 7 Off
Off
Off
Off
Off
Off
Off
Off
10
P13
Drum (Motor)
Torq(ue)
Thres(hold)
10
1500
750
Motor stops if threshold
exceeded. Approx 250
counts/amp of motor current.
P14
Door (Motor)
Torq(ue)
Thres(hold)
10
1500
750
Motor stops if threshold
exceeded. Approx 250
counts/amp of motor current.
P15
Lift (Motor)
Torq(ue)
Thres(hold)
10
1500
750
Motor stops if threshold
exceeded. Approx 250
counts/motor current.
P16
Basket In Time
10
1500
mS
150
Time the basket must remain in
to trigger a dispense
cycle
150 350 150 150 150 150 150
150
150
150
150