F3D3
Series
Service Manual Factory Level 3 Parameter Access / 1.11
Questions? Call Franke Technical Support Group For Your Area. Copyright
2012 Franke, Inc. All rights reserved.
Parameter Access & Software Version
F3D3 Series Fries Dispensers provide easy access to
Factory Level operating and service diagnostic
parameters using the front operator interface touch
panel & display. To access:
1)
Leave unit plugged in.
2)
Turn Main Power Switch
ON*
.
3)
Lane power must be
OFF
. Display will be blank or
show current freezer temperature, depending on
the model and lane.
For To Access Factory Level 3 Parameters:
Step
Action Required
Resulting Display
1
From Standby condition use 3
rd
touchpad to enter:
3
3 3 3
. [The Entry Code]
Special Mode Select
Cust Fact Exit
2
Press touchpad 2 = Fact(ory)
Factory Access Level
Lev1 Lev3 Exit
3
Press touchpad 2 = Lev3
Password ??
Enter Password
0
_ _ _
Inc OK Exit
4A
Press touchpad 2 = OK [Icon will move right to next
digit]
Password ??
Enter Password
0
0
_ _
Inc OK Exit
4B
Press touchpad 2 = OK [Icon will move right to next
digit]
Password ??
Enter Password
0 0
0
_
Inc OK Exit
4C
Press touchpad 2 = OK [Icon will move right to last
digit], then:
Password ??
Enter Password
0 0 0
0
Inc OK Exit
4D
Press touchpad 1 = Inc once, to raise to 1, then:
Password ??
Enter Password
0 0 0 1
Inc OK Exit
5
Press touchpad 2 = OK
Language [first Parameter]
P01 = English
++ -- ->
For F3D3 Software Version
To ID Version:
Use Table:
Software Version BL 2.00; APP 2.12a
On Lane Display
Parameter Table
1.11.1
Software Version:
H47C1
On Chip Label*
Parameter Table
1.11.2
Software Version:
H46P9
On Chip Label*
Parameter Table
1.11.3
∗
NOTE:
The chip version is also displayed briefly
during the
startup sequence
(after Calibration Values), when the Main
POWER-ON switch is first turned ON. It appears as: Firmware =
H47C1, etc. on the second line.
Rev. 1 11/2012
NOTE: All programming is done using the three
choice buttons labeled: 1, 2 and 3 above.
1
2
3