Setting the parameters
☞
The parameters for exposure time and cooling time cannot be set independently of
each other.
11.16
Press and hold the RESET key.
11.17
Additionally press the
OFF key within 2s.
• The LED flashes 4 × briefly.
• The fitting switches to Normal Mode.
• The LED flashes twice with a 1s interval.
11.18
Use keys + and – (
) to set the code for the desired pair of parameters.
☞
By default, the parameter is set to code 6.
• The LED in the sensor of the fitting confirms the entered code
– LED flashes briefly = unit digit
– LED flashes long = tens digit
Example: The LED flashes 2 x long and 1 x short = Code 21 was set. The exposure
time is 3 min. The cooling time is 10 min.
☞
The parameters for safety window and start delay cannot be set independently of
each other.
11.19
Press and hold the RESET key.
11.20
Additionally press the
OFF key within 2s.
• The LED flashes 4 × briefly.
• The fitting switches to Normal Mode.
• The LED flashes twice with a 1s interval.
11.21
Use keys + and – (
) to set the code for the desired pair of parameters.
Cooling time
0
1 min
3 min
5 min
10 min
Treatment time
3 min
1
6
11
16
21
5 min
2
7
12
17
22
10 min
3
8
13
18
23
15 min
4
9
14
19
24
20 min
5
10
15
20
25