![background image](http://html1.mh-extra.com/html/franke/2000101087/2000101087_installation-and-operating-instructions-manual_2327839021.webp)
21
ZMI
_001_
2000
1010
87-ZAQ
U
A09
1_#S
EN_#A
QU_#V
5.f
m
12. Urinal Settings
Triggering flushing
12.1
Press the
ON key.
• Water flows for the set flushing duration.
Switching 24 hour flushing on/off
☞
Flushing is factory-set to 24 hours.
12.2
Press and hold the RESET key.
12.3
Additionally press the
OFF key within 2s.
• The LED in the sensor of the fitting flashes:
– 4 x short: 24 hour flushing is switched on.
– 2 × long: 24 hour flushing is switched off.
12.4
Wait 10 seconds.
• The system exits from the setting mode.
Resetting default factory settings (Reset)
12.5
Press the RESET key for at least 3 s.
• The system now has the factory settings again.
• The LED in the sensor of the fitting flashes:
– 4 × short, 1 × long, 3 × short, 1 × long, 3 × short
• The fitting is in Power-Up mode:
– Any detected objects are displayed by the LED in the sensor of the fitting.
– There is no minimum dwelling time, i.e. flushing always occurs after the end of
detection, independent of the time spent within the detection area.
☞
Power-Up mode is stopped automatically after 3 minutes. The fitting is now in
normal operation.