13. Additional Settings for the Urinal
☞
These additional settings only apply for concealed urinal fittings with mains power operation.
Switching preliminary flushing on/off
☞
The preliminary flushing is switched off at the factory.
13.1
Press and hold the TEST key.
13.2
Press the
ON key within 2s.
• The LED in the sensor of the fitting flashes:
– 4 x short: Preliminary flushing is switched on.
– 2 × long: Preliminary flushing is switched off.
13.3
Exit the adjustment mode.
• Press the TEST key.
or
• Wait 60 seconds.
Switching intermediate flushing on/off
☞
Intermediate flushing is factory-set to ON.
13.4
Press and hold the TEST key.
13.5
Additionally press the
OFF key within 2s.
• The LED in the sensor of the fitting flashes:
– 4 x short: Intermediate flushing is switched on.
– 2 × long: Intermediate flushing is switched off.
13.6
Exit the adjustment mode.
• Press the TEST key.
or
• Wait 60 seconds.
Setting the minimum retention time
☞
The minimum dwelling time is factory-set to 7s.
13.7
Press and hold the TEST key.
13.8
Use the + and – (
) keys to adjust the minimum retention time in individual steps.
• The LED in the sensor of the fitting flashes:
– 4 × short for each adjustment by one step (approx. 1s)
– 2 x long when the respective end setting is reached
13.9
Exit the adjustment mode.
• Press the TEST key.
or
• Wait 60 seconds.