The impeller has accumulated deposits.
Have the unit cleaned inside by FPZ After-Sales Service.
G
Unit fixed without vibration dampers.
Have the unit secured with vibration dampers by the
Technician.
F
Rigid connection to the system
Have flexible sleeves installed between the unit and the
pipes by the Technician.
G
Faulty bearing on blower side or motor side.
Have the bearing replaced by FPZ After-Sales Service.
Fluid leakage
G
Faulty gaskets on the silencer.
Have the gaskets checked and, if necessary, replaced by
FPZ After-Sales Service.
G
Faulty gaskets on the cover.
Have the gaskets checked and, if necessary, replaced by
FPZ After-Sales Service.
G
Leaks from mechanical seals
Have the seals checked and, if necessary, replaced by
FPZ After-Sales Service.
Intervention of one
or more sensors
F
False alarms
Check the alarm and shutdown system.
G
Pressure switch or vacuum switch
intervention
Check the system and have the machine
inspected/repaired by FPZ After-Sales Service
G
Overheating with temperature sensor
intervention
G
Excessive vibration with vibration sensor
intervention