background image

Greenfi re GF45 BioEnergy Stove

5

INST

ALLA

TION

IMPORTANT: SAVE THESE INSTRUCTIONS

The GF45 Stove must be installed in  accordance with these instructions. 
Carefully read all the instructions in this manual fi rst. Consult the building 
authority having jurisdiction to determine the need for a permit prior to 
starting the installation.

NOTE: 

 Failure to follow the instructions could cause a malfunction of the 

heater which could result in death, serious bodily injury, and/or property 
damage.  Failure to follow these instructions may also void your fi re 
insurance and/or warranty. 

BEFORE YOU START

It is very important to ensure that the stove is installed in a safe manner.  
Be aware of fi re prevention rules and laws in your area. All applicable 
National and Local codes must be met and complied with.

We recommend that your pellet stove be installed by an authorized 
dealer / installer.

The stove’s electrical connection is to a standard grounded wall socket. 
Special care should be taken so the connection cable is not damaged 
in any way.

It is strongly recommended that you install a smoke detector as well as 
an ABC type extinguisher near the stove. A power surge bar is also highly 
recommended to protect the electrical components.

If the stove is installed by an uncertifi ed installer, FPI will not be held 
responsible for any faulty operation including poor performance of the 
stove.

IMPORTANT SAFETY INFORMATION  

Only use approved fuels in multi-fuel burning appliances. Failure to comply 
with this may create a hazardous situation and will void all warranties.  

Never attempt to re-start your stove until it has fully cooled down.  Starting 
your stove using a gel is only recommended during automatic ignition 
failure.

Never use or store fl ammable products close to the stove while it’s in use, 
or at any other time.

The Prime button is only used to prime the auger when Hopper is empty. 

 

Do not use

 the manual feeding procedures to start-up your stove as 

these will create smoke in your house.

Ensure that the ash pan door is securely closed at all times when the stove 
is in use. Air pressure could ignite the gas accumulated in the burn-pot 
creating an overdraft condition in the combustion chamber altering the 
performance of the burn-pot.

The GF45 model will not feed fuel if the front door or hopper lid are not 
fully closed and the fi rebox in a negative pressure situation.  These are 
safety functions of the appliance.

INSTALLATION

UNIT LOCATION

1. 

For optimum benefi t from your appliance, speak to your professional 
for help with your location.

2.

  The location you choose for your appliance can be a factor in how 

it will perform. Choose an interior location where the vent will not 
be affected by any external interference, i.e. trees, bushes, walls or 
fencing (refer to "Vent Termination Requirements" section). Make 
sure, at the time of the installation, that there is the least possible 
interference with the existing components of the house. Install a non 
fl ammable covering when necessary. Place the stove according to 
recommendations made on "Clearances" section or according to the 
safety label fi xed on the stove. 

3.

  You can use the wall behind the stove to pass the chimney system 

or simply join the stove to an existing chimney or a metal chimney, 
with the use of an approved liner. 

4.

  Ensure that all clearances to combustibles are met as per the safety 

label and the diagrams on "Clearances" section. 

5.

 

This appliance requires outside air.

 Make sure that the outside 

air supply does not come from a garage, an attic or any restricted 
non-ventilated space.  Air must come from the outside of the house 
directly into the back of the stove. 

6.

  This stove is not approved to be installed into a bedroom under any 

circumstances.

7.

  The fl ooring under the stove must be made of a non-combustible 

material, i.e. cement, ceramics, etc, and must extend at least 6" 
(152mm) all around the stove. Refer to the diagrams on "Clearances" 
section.

WHAT IS INCLUDED WITH THE GF45

Qty

   

Description

1 pc 

User Manual 

1 pc 

AC Power Inlet 

 

1 pc 

Measuring Cup 

 

1 pc 

Pipe Adapter Gasket 

 

  

(for Pressure Reducer Plate)

1 pc 

Pressure Reducer Plate 1-1/4"

1 pc 

Pressure Reducer Plate 1-5/8"

1 pc 

Ash Poker

1 pc 

7ft. 6in. Extension Cord

1 pc 

Outside Air Kit

IMPORTANT:

 

Stove must be cold before any attempt to clean the glass is made. Do 
not use detergent containing abrasives to clean the windows or any 
other parts of the stove.  Use only recommended products found at 
your local hearth shop for this type of cleaning.

IMPORTANT:

 

When cleaning the stove, always remove ashes into a steel container 
and place outside the residence. Use gloves to handle or to empty 
the ash pan. 

IMPORTANT:

 

Before servicing the electrical panel, make sure that all electrical 
sources is turned off to the stove and the 

power disconnected.

 Do 

not forget to disconnect the battery, control board, fans and switches 
as well.

Содержание Dell-Point GF45

Страница 1: ...uel burning room heater Failuretofollowtheseinstructionscouldresultin property damage bodily injury or even death Contact local building or re of cials about restrictions and installation inspection r...

Страница 2: ...about your product that are not covered in this manual please contact the FPI DEALER in your area Keep those FPI FIRES burning Safety Note If this stove is not properly installed a house re may result...

Страница 3: ...INSTRUCTIONS Control Panel Functions 15 Starting Procedures 16 To Start Your Stove 16 Priming Stove Empty Hopper 16 Burning Wood Pellets Primed Hopper 16 To Stop Stove 16 Operation Guidelines for Burn...

Страница 4: ...anieseach GF45 We have printed a copy of the contents here for your review The safety label is located on the back panel of the stove NOTE FPI units are constantly being improved Check the label on th...

Страница 5: ...rebox in a negative pressure situation These are safety functions of the appliance INSTALLATION UNIT LOCATION 1 For optimum bene t from your appliance speak to your professional for help with your lo...

Страница 6: ...e fans consume an average of 200 cfm which is more powerful than the combustionfanontheGF45 creatingnegativepressurearoundthestove To overcome this negative pressure the GF45 requires the installation...

Страница 7: ...LLATION INSTALLATION UNIT DIMENSIONS CLEARANCES Alcove Ceiling height is 60 324mm measured from bottom of the unit Floor Protector of 0 84k factor minimum is required beneath the Hearth Please check w...

Страница 8: ...or paved driveway which is located between two single family dwellings and serves both dwellings If the vent termination is accessible a certi ed guard shall be installed Local codes or regulations s...

Страница 9: ...Green re GF45 BioEnergy Stove 9 INSTALLATION INSTALLATION HORIZONTAL TERMINATION Top View Side View...

Страница 10: ...Green re GF45 BioEnergy Stove 10 INSTALLATION OUTSIDE VERTICAL TERMINATION INSTALLATION Side View...

Страница 11: ...Green re GF45 BioEnergy Stove 11 INSTALLATION INSTALLATION VERTICAL TERMINATION Top View Side View Diagram 6...

Страница 12: ...Green re GF45 BioEnergy Stove 12 INSTALLATION EXISTING CLASS A CHIMNEY INSTALLATION Diagram 7...

Страница 13: ...Green re GF45 BioEnergy Stove 13 INSTALLATION INSTALLATION EXISTING MASONRY CHIMNEY Diagram 8...

Страница 14: ...ere it left off upon restoration of power To facilitate the installation of a larger 12 volt battery we include exten sion alligator clip leads in the battery installation kit Note 12 volt batteries s...

Страница 15: ...elect the appropriate fuel type that is going to be burned Heat Level Settings Select the desired heat level by pressing buttons Heat levels range from 1 to 5 for all fuels Service Allows you to chang...

Страница 16: ...ht attempts To Start Your Stove To facilitate your start up and regardless of fuel being utilized in your stove you must use wood pellets as fuel for starting This will quickly raise the burner and ve...

Страница 17: ...u continue to use the same fuel i e Corn or Wheat Burn pot fuel bed If you cannot see 5 of the burn pot wall above your fuel ember bed the level is too high refer to Diagram 9b in Low Fuel Ember Bed C...

Страница 18: ...CLEAN THE COMBUSTION FAN FLYWHEEL X INSPECT THE SEALS X CLEAN THE CHIMNEY X INSPECT IGNITOR TUBES X COMPONENTS OF STOVE EACH START UP WEEKLY MONTHLY ANNUALLY REMOVE ASHES IN BURN POT X CHECK THE ASH R...

Страница 19: ...er avoid the use of a domestic style vacuum cleaner with lter only when the stove is cold to remove the ashes accumulated around the burn pot Diagram 10 Clean the interior of the glass door Use the sh...

Страница 20: ...corn or wheat can stick to the ash screws resulting in poor movement and ash removal Check by removing the ash extraction system or look inside the burn pot Diagram 16 Diagram 15 Step 2 Use a 9 16 wre...

Страница 21: ...iagram 26 Give the piece of paper a little tug and if it slips out easily the gaskets need to be replaced Use only approved gasket and adhesive obtainable from your FPI dealer A proper high temperatur...

Страница 22: ...ngs 5 levels of heat Electrical Min Capacity 25 amps 120 volts 120 volts or 240 volts AC 15 amps 240 volts Max Capacity 65 amps 120 volts 35 amps 240 volts 12 volts DC Min Capacity 1 8 amps 13 8 Volts...

Страница 23: ...the startup procedures as listed in the manual System Shutdown Contact Dealer a The feed auger fuse is blown Unit will go into shutdown mode After shutdown the screen will display Fuse Error EFF b The...

Страница 24: ...Pin 3 4 orange wires safety Pin 16 red wire Convection fan Pin 5 6 green wires safety Pin 17 black wire input Pin 7 black wire feed system Pin 18 white wire protection Pin 8 yellow wire feed system Pi...

Страница 25: ..._________ ___________________________________________________ ___________________________________________________ ___________________________________________________ __________________________________...

Страница 26: ..._______________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ____________________________...

Страница 27: ...er name purchase date model serial number problem parts requested Without this information the claim will be invalid Warranty is only valid if the maintenace schedule is followed as listed in the manu...

Страница 28: ...Printed in Canada Copyright 2006 FPI Fireplace Products International Ltd All rights reserved...

Отзывы: