background image

Greenfi re GF45 BioEnergy Stove

16

OPERA

TION

OPERATING INSTRUCTIONS

Priming Stove: Empty Hopper 

1)  

Open the Hopper Lid and fi ll with desired fuel to be burned.

 

NOTE: 

The Hopper can hold up to a 45 pound bag of fuel.

2)

  Close Hopper Lid.

3)

  Open the front door and place the measuring cup in the center of the burn 

pot directly under the feed tube. The measuring cup will need to be tilted 
in order to fi t under the feed tube.

4)

  Close the Front Door. 

5)

  Open the Control Panel Cover and press the “Prime Stove” button once. 

The Control Panel screen will display 

Prime Feed

.

6)

  Wait 2 minutes to allow for the stove to prime. While the stove is priming 

you will see fuel spilling into the measuring cup.

7)

  After 2 minutes the Control Panel will return to the main screen. Open 

the front door and remove the measuring cup from the burn pot and pour 
the fuel back into the hopper.

8)

  Close Hopper Lid and Front Door.

9)  

Proceed to the steps below to burning the desired fuel type.

NOTE: If the stove does not prime within 2 minutes, ensure that the Hopper 
Lid and Front Door are properly closed. (The stove will not prime if the 
front door or hopper lid are open.) Press the “Prime” button again.

Burning Wood Pellets: Primed Hopper 

NOTE: If the hopper is empty, follow steps 1 to 8 to Prime Stove.

1) 

Open the control panel cover, and select the fuel type by pressing the 
“Select Fuel” button until the screen displays 

Wood

.  The optional Green-

Key is only needed for additional fuels, without it the unit will burn wood 
pellets only.

2)

  To ignite the stove press the “Start” button once and the screen will display 

Ignition

Do not add any fuel to the burn pot.  In Wood mode the stove 

will fi ll the burn pot before starting ignition.

3)

  The ignition sequence will take approximately 7 minutes to complete.  

After 3-4 minutes you should start to see smoke coming from the burn 
pot. 

This is normal

, it means that the igniter is working. When the pellets 

ignite and fl ames appear the smoke will disappear.

IMPORTANT:

 

On start up, always use wood pellets when 
operating unit from a cold start. Wood pellets 
ensure a faster and hotter starting fi re  which 
results in better performance.

STARTING 

PROCEDURES

CAUTION: Do Not use the manual priming procedure for 
starting of your stove as this may cause smoke in your resi-
dence. Like all solid fuel fi res, the initial start-up is crucial to 
the ongoing performance of your appliance. Failure to start 
your fi re properly can lead to frustrations and continued 
re-light attempts. 

To Start Your Stove

To facilitate your start up and regardless of fuel being utilized in your 
stove, you must use wood pellets as fuel for starting. This will quickly 
raise the burner and vent temperatures providing a better and faster start 
up. Failure to use wood pellets will not ignite the stove. 

Before starting 

each fi re, fi rst make sure the burn pot is completely emptied out. 

Never attempt to start with a partly fi lled burn pot.

OPERATION GUIDELINES FOR 

BURNING CORN & WHEAT

IMPORTANT: Compared to wood pellets, agricultural based 
fuels such as Corn or Wheat require extra care, attention 
and understanding. Failure to adhere to these operating 
instructions could lead to Ash Auger failure, and /or build up 
of ash in the Burn-pot leading to system failure. Such issues 
are at the control of the operator and not to be considered 
appliance problems. The physical characteristics and 
composition of Corn and Wheat, are very different to that 
of wood. Following these guidelines and directions will help 
you better understand and control the performance of your 
appliance while burning Corn or Wheat.

When burning Corn or Wheat, the following will help you understand and 
establish control of the working parameters of the appliance for optimum 
performance during operation.

Initial Use Of GF45 For 

Burning Corn & Wheat

In order to become better acquainted with this new technology, we recom-
mend to the fi rst time user of wood pellet fuel only for the fi rst few days.  
Once you are comfortable with the functions of the control pad and the 
changes in operation when using the controls with wood pellets, you can 
feel safe to move on to burning Corn or Wheat. Remember regardless 
of the fuel you will be burning from your hopper, 

wood pellets must be 

used to start your fi re

.

NOTE:

 To further ensure your start-up, after the initial 37 minutes, you 

now have control of the keypad for adjustment purposes. However, the 
keypad is protected to only allow single incremental rises and drops in 
fuel feed for 25 minutes at a time. This means should you enter two level 
changes to feed rate, i.e. from 3 to 5, the feed rate will fi rst stabilize on 
4 (3 lbs per hour) for a period of 25 minutes before increasing to 5 (4 lbs 
per hour). This is to allow the fi re to build up rather than create a potential 
for extinguishing your fi re.

As FPI does not have any control on quality or even the type of fuel mar-
keted, they assume no responsibility from any faulty operation related to 
the type of fuel employed. 

To Stop Stove 

NOTE: The unit will take 120 minutes to shutdown completely. 

1)

  Press the “Stop” button on the control panel.

2)

  The screen display will show Shut Down.

Содержание Dell-Point GF45

Страница 1: ...uel burning room heater Failuretofollowtheseinstructionscouldresultin property damage bodily injury or even death Contact local building or re of cials about restrictions and installation inspection r...

Страница 2: ...about your product that are not covered in this manual please contact the FPI DEALER in your area Keep those FPI FIRES burning Safety Note If this stove is not properly installed a house re may result...

Страница 3: ...INSTRUCTIONS Control Panel Functions 15 Starting Procedures 16 To Start Your Stove 16 Priming Stove Empty Hopper 16 Burning Wood Pellets Primed Hopper 16 To Stop Stove 16 Operation Guidelines for Burn...

Страница 4: ...anieseach GF45 We have printed a copy of the contents here for your review The safety label is located on the back panel of the stove NOTE FPI units are constantly being improved Check the label on th...

Страница 5: ...rebox in a negative pressure situation These are safety functions of the appliance INSTALLATION UNIT LOCATION 1 For optimum bene t from your appliance speak to your professional for help with your lo...

Страница 6: ...e fans consume an average of 200 cfm which is more powerful than the combustionfanontheGF45 creatingnegativepressurearoundthestove To overcome this negative pressure the GF45 requires the installation...

Страница 7: ...LLATION INSTALLATION UNIT DIMENSIONS CLEARANCES Alcove Ceiling height is 60 324mm measured from bottom of the unit Floor Protector of 0 84k factor minimum is required beneath the Hearth Please check w...

Страница 8: ...or paved driveway which is located between two single family dwellings and serves both dwellings If the vent termination is accessible a certi ed guard shall be installed Local codes or regulations s...

Страница 9: ...Green re GF45 BioEnergy Stove 9 INSTALLATION INSTALLATION HORIZONTAL TERMINATION Top View Side View...

Страница 10: ...Green re GF45 BioEnergy Stove 10 INSTALLATION OUTSIDE VERTICAL TERMINATION INSTALLATION Side View...

Страница 11: ...Green re GF45 BioEnergy Stove 11 INSTALLATION INSTALLATION VERTICAL TERMINATION Top View Side View Diagram 6...

Страница 12: ...Green re GF45 BioEnergy Stove 12 INSTALLATION EXISTING CLASS A CHIMNEY INSTALLATION Diagram 7...

Страница 13: ...Green re GF45 BioEnergy Stove 13 INSTALLATION INSTALLATION EXISTING MASONRY CHIMNEY Diagram 8...

Страница 14: ...ere it left off upon restoration of power To facilitate the installation of a larger 12 volt battery we include exten sion alligator clip leads in the battery installation kit Note 12 volt batteries s...

Страница 15: ...elect the appropriate fuel type that is going to be burned Heat Level Settings Select the desired heat level by pressing buttons Heat levels range from 1 to 5 for all fuels Service Allows you to chang...

Страница 16: ...ht attempts To Start Your Stove To facilitate your start up and regardless of fuel being utilized in your stove you must use wood pellets as fuel for starting This will quickly raise the burner and ve...

Страница 17: ...u continue to use the same fuel i e Corn or Wheat Burn pot fuel bed If you cannot see 5 of the burn pot wall above your fuel ember bed the level is too high refer to Diagram 9b in Low Fuel Ember Bed C...

Страница 18: ...CLEAN THE COMBUSTION FAN FLYWHEEL X INSPECT THE SEALS X CLEAN THE CHIMNEY X INSPECT IGNITOR TUBES X COMPONENTS OF STOVE EACH START UP WEEKLY MONTHLY ANNUALLY REMOVE ASHES IN BURN POT X CHECK THE ASH R...

Страница 19: ...er avoid the use of a domestic style vacuum cleaner with lter only when the stove is cold to remove the ashes accumulated around the burn pot Diagram 10 Clean the interior of the glass door Use the sh...

Страница 20: ...corn or wheat can stick to the ash screws resulting in poor movement and ash removal Check by removing the ash extraction system or look inside the burn pot Diagram 16 Diagram 15 Step 2 Use a 9 16 wre...

Страница 21: ...iagram 26 Give the piece of paper a little tug and if it slips out easily the gaskets need to be replaced Use only approved gasket and adhesive obtainable from your FPI dealer A proper high temperatur...

Страница 22: ...ngs 5 levels of heat Electrical Min Capacity 25 amps 120 volts 120 volts or 240 volts AC 15 amps 240 volts Max Capacity 65 amps 120 volts 35 amps 240 volts 12 volts DC Min Capacity 1 8 amps 13 8 Volts...

Страница 23: ...the startup procedures as listed in the manual System Shutdown Contact Dealer a The feed auger fuse is blown Unit will go into shutdown mode After shutdown the screen will display Fuse Error EFF b The...

Страница 24: ...Pin 3 4 orange wires safety Pin 16 red wire Convection fan Pin 5 6 green wires safety Pin 17 black wire input Pin 7 black wire feed system Pin 18 white wire protection Pin 8 yellow wire feed system Pi...

Страница 25: ..._________ ___________________________________________________ ___________________________________________________ ___________________________________________________ __________________________________...

Страница 26: ..._______________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ____________________________...

Страница 27: ...er name purchase date model serial number problem parts requested Without this information the claim will be invalid Warranty is only valid if the maintenace schedule is followed as listed in the manu...

Страница 28: ...Printed in Canada Copyright 2006 FPI Fireplace Products International Ltd All rights reserved...

Отзывы: