background image

Greenfi re GF45 BioEnergy Stove

27

WARRANTY

GF45 MANUFACTURERS WARRANTY

FPI offers a Limited Lifetime warranty, consisting of fi ve years parts and *subsidized labor and parts only thereafter against manufacturers defects 
on the steel structure of the appliance and the burn pot.

FPI offers two years parts and *subsidized labor and 5 years parts only thereafter against manufacturers defects on fans, motors and the auger 
motor.

FPI offers two years parts and *subsidized labor and one year parts only thereafter against manufacturers defects on the fan controller, power 
supply and ceramic glass.

FPI offers two years parts and *subsidized labor against manufacturers defects on the control board.

FPI offers 6 months against manufacturers defects on the battery from the date of purchase.

Conditions:

The warranty will commence on the purchase date of the appliance to the original purchaser.

Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at FPI’s option through an authorized 
distributor or agent provided that the replaced part is returned to FPI via the distributor or agent Transportation Prepaid. 

Replacement parts may be charged for until replacements are evaluated for manufacturers defects.

The authorized selling dealer is responsible for all in-fi eld warranty and service work carried out on the FPI product. FPI will not be responsible or 
liable for results or costs of workmanship carried out by unauthorized service persons or dealers.

At all times, FPI reserves the right to inspect product in the fi eld which is claimed to be defective.

All claims must be submitted to FPI by the authorized selling dealer. It is necessary and essential that all claims submitted provide all requested 
information for process to commence. i.e. Customer name, purchase date, model, serial number, problem, parts requested. Without this information, 
the claim will be invalid.

Warranty is only valid if the maintenace schedule is followed as listed in the manual.
 

Exclusions:

The warranty does not extend to gasketing, paint or trim.

At no time will FPI be liable for any consequential damages which exceed the original price of the unit.

FPI has no obligation to enhance or modify any unit once manufactured, i.e. as products evolve, fi eld modifi cations or upgrades will not be per
formed on existing appliances.

FPI will not be liable for travel costs for service work.

Installation, environmental, and user problems, are not the responsibility of the manufacturer and therefore not covered under the terms of the 
warranty policy.

Units showing signs of neglect or mis-use are not covered under the terms of the warranty policy.

Warranty will not extend to any part or parts which have been tampered with or altered in any way, or which in our judgement has been subject to 
mis-use, lack of maintenance, improper installation, neglect or accident, spillage, downdrafts caused by environmental or geographical conditions, 
inadequate ventilation, excessive offsets, negative air pressure caused by mechanical systems such as furnaces, fans, clothes dryers etc.

Freight damage to stoves and replacement parts is subject to a claim against the freight carrier by the dealer and therefore not covered by the 
warranty.

FPI will not be liable for acts of God or acts of terrorism which causes malfunction of the appliance.

Performance problems due to operator error will not be covered by this warranty policy.

Products made or provided by other manufacturers and used in conjunction with the operation of this appliance without prior authorization from 
FPI may nullify your warranty.

Any alteration that causes leaks from the appliance or venting is not the responsibility of FPI and therefore not covered under the warranty policy.

* Subsidy according to job scale predetermined by FPI. 

Содержание Dell-Point GF45

Страница 1: ...uel burning room heater Failuretofollowtheseinstructionscouldresultin property damage bodily injury or even death Contact local building or re of cials about restrictions and installation inspection r...

Страница 2: ...about your product that are not covered in this manual please contact the FPI DEALER in your area Keep those FPI FIRES burning Safety Note If this stove is not properly installed a house re may result...

Страница 3: ...INSTRUCTIONS Control Panel Functions 15 Starting Procedures 16 To Start Your Stove 16 Priming Stove Empty Hopper 16 Burning Wood Pellets Primed Hopper 16 To Stop Stove 16 Operation Guidelines for Burn...

Страница 4: ...anieseach GF45 We have printed a copy of the contents here for your review The safety label is located on the back panel of the stove NOTE FPI units are constantly being improved Check the label on th...

Страница 5: ...rebox in a negative pressure situation These are safety functions of the appliance INSTALLATION UNIT LOCATION 1 For optimum bene t from your appliance speak to your professional for help with your lo...

Страница 6: ...e fans consume an average of 200 cfm which is more powerful than the combustionfanontheGF45 creatingnegativepressurearoundthestove To overcome this negative pressure the GF45 requires the installation...

Страница 7: ...LLATION INSTALLATION UNIT DIMENSIONS CLEARANCES Alcove Ceiling height is 60 324mm measured from bottom of the unit Floor Protector of 0 84k factor minimum is required beneath the Hearth Please check w...

Страница 8: ...or paved driveway which is located between two single family dwellings and serves both dwellings If the vent termination is accessible a certi ed guard shall be installed Local codes or regulations s...

Страница 9: ...Green re GF45 BioEnergy Stove 9 INSTALLATION INSTALLATION HORIZONTAL TERMINATION Top View Side View...

Страница 10: ...Green re GF45 BioEnergy Stove 10 INSTALLATION OUTSIDE VERTICAL TERMINATION INSTALLATION Side View...

Страница 11: ...Green re GF45 BioEnergy Stove 11 INSTALLATION INSTALLATION VERTICAL TERMINATION Top View Side View Diagram 6...

Страница 12: ...Green re GF45 BioEnergy Stove 12 INSTALLATION EXISTING CLASS A CHIMNEY INSTALLATION Diagram 7...

Страница 13: ...Green re GF45 BioEnergy Stove 13 INSTALLATION INSTALLATION EXISTING MASONRY CHIMNEY Diagram 8...

Страница 14: ...ere it left off upon restoration of power To facilitate the installation of a larger 12 volt battery we include exten sion alligator clip leads in the battery installation kit Note 12 volt batteries s...

Страница 15: ...elect the appropriate fuel type that is going to be burned Heat Level Settings Select the desired heat level by pressing buttons Heat levels range from 1 to 5 for all fuels Service Allows you to chang...

Страница 16: ...ht attempts To Start Your Stove To facilitate your start up and regardless of fuel being utilized in your stove you must use wood pellets as fuel for starting This will quickly raise the burner and ve...

Страница 17: ...u continue to use the same fuel i e Corn or Wheat Burn pot fuel bed If you cannot see 5 of the burn pot wall above your fuel ember bed the level is too high refer to Diagram 9b in Low Fuel Ember Bed C...

Страница 18: ...CLEAN THE COMBUSTION FAN FLYWHEEL X INSPECT THE SEALS X CLEAN THE CHIMNEY X INSPECT IGNITOR TUBES X COMPONENTS OF STOVE EACH START UP WEEKLY MONTHLY ANNUALLY REMOVE ASHES IN BURN POT X CHECK THE ASH R...

Страница 19: ...er avoid the use of a domestic style vacuum cleaner with lter only when the stove is cold to remove the ashes accumulated around the burn pot Diagram 10 Clean the interior of the glass door Use the sh...

Страница 20: ...corn or wheat can stick to the ash screws resulting in poor movement and ash removal Check by removing the ash extraction system or look inside the burn pot Diagram 16 Diagram 15 Step 2 Use a 9 16 wre...

Страница 21: ...iagram 26 Give the piece of paper a little tug and if it slips out easily the gaskets need to be replaced Use only approved gasket and adhesive obtainable from your FPI dealer A proper high temperatur...

Страница 22: ...ngs 5 levels of heat Electrical Min Capacity 25 amps 120 volts 120 volts or 240 volts AC 15 amps 240 volts Max Capacity 65 amps 120 volts 35 amps 240 volts 12 volts DC Min Capacity 1 8 amps 13 8 Volts...

Страница 23: ...the startup procedures as listed in the manual System Shutdown Contact Dealer a The feed auger fuse is blown Unit will go into shutdown mode After shutdown the screen will display Fuse Error EFF b The...

Страница 24: ...Pin 3 4 orange wires safety Pin 16 red wire Convection fan Pin 5 6 green wires safety Pin 17 black wire input Pin 7 black wire feed system Pin 18 white wire protection Pin 8 yellow wire feed system Pi...

Страница 25: ..._________ ___________________________________________________ ___________________________________________________ ___________________________________________________ __________________________________...

Страница 26: ..._______________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ____________________________...

Страница 27: ...er name purchase date model serial number problem parts requested Without this information the claim will be invalid Warranty is only valid if the maintenace schedule is followed as listed in the manu...

Страница 28: ...Printed in Canada Copyright 2006 FPI Fireplace Products International Ltd All rights reserved...

Отзывы: