Greenfi re GF45 BioEnergy Stove

17

OPERA

TION

OPERATING INSTRUCTIONS

Burning Corn or Wheat: Primed Hopper 

NOTE: If the hopper is empty, follow steps 1 to 8 to Prime Stove.

1) 

  Open the control panel cover,  if the GreenKey has not yet been inserted  

gently push the key into the keyhole on the control panel.

2)

  Select the fuel type by pressing the “Select Fuel” button until the appropri-

ate fuel type is displayed on the screen.

3)

  Press the “Start” button and the screen will display 

Manual Light.

4)

  Open the front door and pour 2-1/2 cups of wood pellets into the burn 

pot. Ensure that the pellets are levelled out & cover the ignitor hole.

5)

  Close the front door.

6)

  Press the “Start” button again and the screen will display

 

Ignition.

7)

  The ignition sequence will take approximately 7 minutes to complete.  

After 3-4 minutes you should start to see smoke coming from the burn 
pot. 

This is normal

, it means that the igniter is working. When the pellets 

light and fl ames appear the smoke will disappear.

Selecting Proper Fuel Type

If you forget to select the proper fuel type. ie. set at wood but hopper is fi lled 
with corn, the burn pot will fi ll with corn or wheat and will start smoking. 
Immediately press the 'Stop' button and allow the unit to clean itself out. 
The shutdown process will empty burn pot which takes 120 minutes.

NOTE:

 Do not open the door at any time.

Clinker Prevention

Clinkers are a result of incomplete combustion in your burn-pot and, if by 
chance they occur, can be controlled with correct use of your controls. 
Incomplete and poor combustion in your appliance is related to the level 
of the fuel bed height, the level of combustion air, the temperatures in 
your burn-pot, and the rate of ash extraction from your burn-pot.

 In the event that  clinkers start to form , you can use the “poker” provided 
to gently break this formation and allow the unit to then continue as before. 
If you must open the fi rebox door while the unit is in operation, (to break 
a clinker), always open gently and slowly.

Diagram 9a: Calibration Indicator / Pressure Gauge

(located below control panel at the side of the unit)

High Fuel / Ember Bed Control

If under the above display conditions, you have accumulated a high 
fuel/ember bed, the following guidelines should help you eliminate the 
problem and stabilize the fuel bed for future use. These should be one-
time changes and settings for as long as you continue to use the same 
fuel. i.e. Corn or Wheat.

Burn-pot fuel bed

:  If you cannot see 5” of  the burn-pot wall above your 

fuel/ember bed, the level is too high (refer to Diagram 9b in "Low Fuel/
Ember Bed Control" section).

1)

   Hold the 'Service' button down for approximately 6 seconds.

Low Fuel/ember Bed Control

If under above display conditions, you have accumulated a low fuel/ember 
bed the following guidelines should help you eliminate the problem and 
stabilize the fuel bed for future use.

Burn-pot fuel bed: 

 If you see more than 5 ½” - 6” of  the burn-pot wall 

above your fuel/ember bed, the level is too low (refer to Diagram 9b).

After the initial start-up procedures and the unit has run undisturbed or 
unaltered for at least one hour, visually check the combustion air fl ow and 
ash removal indicator levels on the control panel by holding the 'Service' 
button for approximately 6 seconds and check the settings for FAN and 
ASH. They should read “10”.

If under these display conditions, you have a 

low fuel/ember bed

, the fol-

lowing guidelines should help you eliminate the problem and stabilize the 
fuel bed for future use. These should be one-time changes and settings for 
as long as you continue to use the same fuel. i.e. Corn or Wheat.

1)

   Hold the 'Service' button down for approximately 6 seconds.

2)

    When FAN displays on the screen, gradually decrease the combustion 

air to digital reading of “8” by pressing the "-" button. The default is 
10, it ranges from 1 - 20.

3)

   Press the 'Service' button once and ASH will display, gradually de-

crease the ash removal to digital reading of “8” by pressing the "-" 
button. The default is 10, it ranges from 1 - 20.

4) 

  Press the 'Heat' button once to go back to main screen display.

This will reduce the rate of ash removal, allowing the fuel/ember bed to 
build to the appropriate level. i.e. 5” from the top, or a 3” bed. 

5"

Fuel/Ember Bed

Pellet
Feed
Tube

Ash Extraction
(Auger)

Diagram 9b

2)

    When FAN displays on the screen, gradually increase the combustion 

air to digital reading of “12” by pressing the "+" button. The default 
is 10, it ranges from 1 - 20.

3)

   Press the 'Service' button once and ASH will display, gradually in-

crease the ash removal to digital reading of “12” by pressing the "+" 
button. The default is 10, it ranges from 1 - 20.

4) 

  Press the 'Heat' button once to go back to main screen display.

At this point you will notice an increase in the pressure reading on the 
round Pressure Gauge (refer to Diagram 9a)  indicator located below the 
control panel. This will fl uctuate as you increase or decrease air fl ow. (This 
is a good indicator to help you manage your settings.

Содержание Dell-Point GF45

Страница 1: ...uel burning room heater Failuretofollowtheseinstructionscouldresultin property damage bodily injury or even death Contact local building or re of cials about restrictions and installation inspection r...

Страница 2: ...about your product that are not covered in this manual please contact the FPI DEALER in your area Keep those FPI FIRES burning Safety Note If this stove is not properly installed a house re may result...

Страница 3: ...INSTRUCTIONS Control Panel Functions 15 Starting Procedures 16 To Start Your Stove 16 Priming Stove Empty Hopper 16 Burning Wood Pellets Primed Hopper 16 To Stop Stove 16 Operation Guidelines for Burn...

Страница 4: ...anieseach GF45 We have printed a copy of the contents here for your review The safety label is located on the back panel of the stove NOTE FPI units are constantly being improved Check the label on th...

Страница 5: ...rebox in a negative pressure situation These are safety functions of the appliance INSTALLATION UNIT LOCATION 1 For optimum bene t from your appliance speak to your professional for help with your lo...

Страница 6: ...e fans consume an average of 200 cfm which is more powerful than the combustionfanontheGF45 creatingnegativepressurearoundthestove To overcome this negative pressure the GF45 requires the installation...

Страница 7: ...LLATION INSTALLATION UNIT DIMENSIONS CLEARANCES Alcove Ceiling height is 60 324mm measured from bottom of the unit Floor Protector of 0 84k factor minimum is required beneath the Hearth Please check w...

Страница 8: ...or paved driveway which is located between two single family dwellings and serves both dwellings If the vent termination is accessible a certi ed guard shall be installed Local codes or regulations s...

Страница 9: ...Green re GF45 BioEnergy Stove 9 INSTALLATION INSTALLATION HORIZONTAL TERMINATION Top View Side View...

Страница 10: ...Green re GF45 BioEnergy Stove 10 INSTALLATION OUTSIDE VERTICAL TERMINATION INSTALLATION Side View...

Страница 11: ...Green re GF45 BioEnergy Stove 11 INSTALLATION INSTALLATION VERTICAL TERMINATION Top View Side View Diagram 6...

Страница 12: ...Green re GF45 BioEnergy Stove 12 INSTALLATION EXISTING CLASS A CHIMNEY INSTALLATION Diagram 7...

Страница 13: ...Green re GF45 BioEnergy Stove 13 INSTALLATION INSTALLATION EXISTING MASONRY CHIMNEY Diagram 8...

Страница 14: ...ere it left off upon restoration of power To facilitate the installation of a larger 12 volt battery we include exten sion alligator clip leads in the battery installation kit Note 12 volt batteries s...

Страница 15: ...elect the appropriate fuel type that is going to be burned Heat Level Settings Select the desired heat level by pressing buttons Heat levels range from 1 to 5 for all fuels Service Allows you to chang...

Страница 16: ...ht attempts To Start Your Stove To facilitate your start up and regardless of fuel being utilized in your stove you must use wood pellets as fuel for starting This will quickly raise the burner and ve...

Страница 17: ...u continue to use the same fuel i e Corn or Wheat Burn pot fuel bed If you cannot see 5 of the burn pot wall above your fuel ember bed the level is too high refer to Diagram 9b in Low Fuel Ember Bed C...

Страница 18: ...CLEAN THE COMBUSTION FAN FLYWHEEL X INSPECT THE SEALS X CLEAN THE CHIMNEY X INSPECT IGNITOR TUBES X COMPONENTS OF STOVE EACH START UP WEEKLY MONTHLY ANNUALLY REMOVE ASHES IN BURN POT X CHECK THE ASH R...

Страница 19: ...er avoid the use of a domestic style vacuum cleaner with lter only when the stove is cold to remove the ashes accumulated around the burn pot Diagram 10 Clean the interior of the glass door Use the sh...

Страница 20: ...corn or wheat can stick to the ash screws resulting in poor movement and ash removal Check by removing the ash extraction system or look inside the burn pot Diagram 16 Diagram 15 Step 2 Use a 9 16 wre...

Страница 21: ...iagram 26 Give the piece of paper a little tug and if it slips out easily the gaskets need to be replaced Use only approved gasket and adhesive obtainable from your FPI dealer A proper high temperatur...

Страница 22: ...ngs 5 levels of heat Electrical Min Capacity 25 amps 120 volts 120 volts or 240 volts AC 15 amps 240 volts Max Capacity 65 amps 120 volts 35 amps 240 volts 12 volts DC Min Capacity 1 8 amps 13 8 Volts...

Страница 23: ...the startup procedures as listed in the manual System Shutdown Contact Dealer a The feed auger fuse is blown Unit will go into shutdown mode After shutdown the screen will display Fuse Error EFF b The...

Страница 24: ...Pin 3 4 orange wires safety Pin 16 red wire Convection fan Pin 5 6 green wires safety Pin 17 black wire input Pin 7 black wire feed system Pin 18 white wire protection Pin 8 yellow wire feed system Pi...

Страница 25: ..._________ ___________________________________________________ ___________________________________________________ ___________________________________________________ __________________________________...

Страница 26: ..._______________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ____________________________...

Страница 27: ...er name purchase date model serial number problem parts requested Without this information the claim will be invalid Warranty is only valid if the maintenace schedule is followed as listed in the manu...

Страница 28: ...Printed in Canada Copyright 2006 FPI Fireplace Products International Ltd All rights reserved...

Отзывы: