Part No.26107 Rev J August 2018
- 26 -
Inline 5000 Series Cabinets
Refrigeration
cont.
REFRIGERATED CABINETS - SERVICING
Condenser
Radiator
For efficient refrigeration
performance, the condenser
radiator must be kept clean.
Failure to do this will lead to
a build-up of dust, and
restricted airflow will
prevent the unit from
working properly. The compressor may overheat
and the cabinet temperature may rise.
Regular vacuuming will prevent a build-up of dust
and fluff, however, three monthly service checks,
which include cleaning of the condenser using C0
2
by a refrigeration engineer, are mandatory.
Be very careful not to bend or damage the soft
aluminium fins when vacuuming the radiator. If the fins are flattened, airflow will
be restricted and overheating will result.
Louver Panels
All louvered panels should be kept free of dust by regular vacuuming, so that air
flow is not restricted.
Continued on next page