![FPG IN 5C08 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/fpg/in-5c08/in-5c08_product-manual_2325948019.webp)
IN 5C08/12/15/18/24.
- 19 -
© Future Products Group
Interior
cont.
REFRIGERATED CABINETS - CLEANING
Cleaning the
Base Cavity
Sweep out, or use a vacuum cleaner, to remove any debris from the cabinet
base cavity.
A Wet-and-Dry vacuum cleaner should be used, since there is likely to be some
water in the bottom. Finally, wipe out the bottom with a damp sanitized cloth.
Do not pour water into the base, or the condensate tray will overflow.
Cooling Fins
If there is food wedged in the cooling fins, it is
best to use a wet and dry vacuum cleaner to
suck out the food. DO NOT attempt to hose food
parts from fins.
Caution:
The fins are very sharp. Take extra
care when cleaning this area. Do not bend the
fins over, as this would restrict the air flow and
degrade cabinet performance.
Temperature
Probes
Take care not to damage or
move the temperature probes,
when cleaning the cooling fins.
One probe is inserted between
the fins of the cooling coil, on
the air-off side.
A second probe is located in the return air flow, on the other side of the cooling
coil.
Do NOT move the probes.
Condensate
Tray
The condensate boil off heater is only designed to handle cooling-coil defrosting
liquid that drains from the well.
DO NOT fill the well with liquid, or attempt to hose out as condensate tray will
overflow and leak onto floor.