IN 5C08/12/15/18/24.
- 23 -
© Future Products Group
SERVICING
Lighting
REFRIGERATED CABINETS
-
SERVICING
Caution
DO NOT service lights without isolating the cabinet at the main switch or
unplugging it from the wall.
Circuit Breaker
All lighting circuits are protected by a circuit
breaker, MCB.
On IN C08/12/15&18 cabinets the circuit
breaker and LED power supplies are located
behind the control panel.
The MCB can be operated via a cut-out in the
top of the chassis.
On the IN 5C24 cabinet, the circuit breaker and
power supplies are located on a separate
chassis, in the base of the cabinet.
Test Lighting
Components
Before replacing an LED strip, check that the power supply is working.
If there is no dc voltage at the output, the power supply should be replaced.
Access to LED
Strips
The LED strips are protected with
plastic covers. These clip into grooves
in the aluminium extrusion.
Remove the plastic cover to access
the LED strip.
The top light assembly is similar to
the shelf lights, but the correct
replacement unit must be used.
LED Strip
Replacement
Individual LED modules cannot be
replaced. A complete light unit must
be used.
Connection is made with a plug and
socket. Disconnect the faulty unit,
and re-connect the replacement unit.
Replace the plastic covers.