49
Model D2424LVmkII Reference Manual (Recording Digital Data)
• Selecting a recording Program
(2)
If you already have multiple Programs, select the
desired Program using the Program Select
function.
* See page “
40
” for more information on the
Program Select function.
• Setting the digital input
(3)
Set up the digital signal to be input and the digital
in clock at the setup mode “Setup of digital inputs”
menu.
The setting of digital input is initially set to “
Analog
”
and digital signals cannot be input.
In order to record external digital signals, “
SP DIF:
Async
,” “
SP DIF: Sync
,” “
adat: Async
” or “
adat: Sync
”
should be setup in accordance to the purpose.
<Notes>
• Do not connect or disconnect the optical cable to
the
[DATA INPUT]
connector when digital input is
assigned. Doing so could generate noise in the
D2424LVmkII and affect the external digital
equipment.
• When the digital input is set to “
adat
” (Async or Sync)
and locked to any one among the three [DATA IN
PUT] (1-8, 9-16, 17-24), “
DIGITAL
” will light in the
display, and the tracks not locked will automatically
change to analog input.
By using this function, analog/digital 24 track
simultaneous recording will be possible by applying
analog signals to tracks 1-8 and adat digital signals
to tracks 9-16 and 17-24.
• Setting recording tracks
(4)
Press the [RECORD TRACK] select keys of the
tracks selected in the digital input track menu to
ready the tracks for recording.
• Recording
(5)
Locate the beginning of the Program.
(6)
Make sure that the “DIGITAL” indicators light up
on the screen. While pressing and holding down
the [RECORD] button, press the [PLAY] button to
start recording.
(7)
Play the external digital device.
Make sure that the level meter segments light up
and move as the digital signal is being input.
• Completing recording
(8)
After you finish recording, stop the recorder and
the connected digital equipment.
"SPDIF:Async":
S/P DIF digital signals from
[DATA INPUT] 1-8
will
be assigned to tracks 1 and 2, and the digital
equipment is synchronized with the internal
clock of the D2424LVmkII.
"SPDIF:Sync":
S/P DIF digital signals from
[DATA INPUT] 1-8
will
be assigned to tracks 1 and 2, and will be syn-
chronized with the S/P DIF digital signals from
the external digital equipment.
"adat:Async"
adat digital signals from
[DATA INPUT] 1-8
,
9-16
and
17-24
will be assigned to tracks 1-8, 9-16
and 17-24 respectively, and the digital equip-
ment synchronized with the internal clock of
D2424LVmkII.
"adat:Sync"
adat digital signals from
[DATA INPUT] 1-8
,
9-16
and
17-24
will be assigned to tracks 1-8, 9-16
and 17-24 respectively, and synchronized with
the adat digital signals from the external digital
equipment.
<Note>:
When the “Setup of digital inputs” is
set to sync mode of “
SPDIF: sync”
or “
adat: Sync”
,
the SETUP mode "
Clock Sel?
" setting will be ig-
nored and the digital-in clock will have priority.
In this case, "
DIGITAL"
and "
EXT
" will light up in
the "
CLOCK
" section of the display.
<Hint!>
When a “
Digital 0 (zero)
” signal is input during
digital recording under the SETUP mode “
Zero
File?
” menu, whether or not a “
0 file
” should be
recorded or not can be setup. Although the “
Zero
File?
” menu is initially set to “
Enable
,” by chang-
ing this to “
Disable
,” a “
0 file
” will not be regis-
tered and the digital signal to be recorded can
be made as “one file.”
For details on the “
Zero File?
” menu, refer to
page “
127.
”
If digital input is set to "
Analog
," "
SPDIF: Async
"
or "
adat: Async
," the SETUP mode "
Clock Sel?
"
(setup of operating clock) must be set up.
* Refer to page “
117
” for setup of “D.in?” menu.