See also the VOLume commands.
ChiMe system tests
See also the VOLume commands.
CONstants interrogation
Clock has a number of standard constants and clock specific standard constants held in the
constants.ini
file on the SD card. These can be used in Nuggle programs and in other ini files
instead of numbers. The
CON
commands allows you to check these constants.
See the Nuggle manual section 2 for more information on constants.
DATe from RTC
The SAM3X8C microcontroller contains a real time clock (RTC) with date and time functions. The
DATe
command allows you to get and set the date.
BEP?
BEeP command help message
BEPS c, f, d
Play a beep
c = channel
1 = right
2 = left
3 = both
f = frequency 30 .. 5000 Hz
d = duration 10 .. 5000 mS
BEPU n
Play a pre-defined beep sequence 0 .. 4
CHM?
CHiMe command help message
CHMK
Kill, stop the current playing chime
CHMR
Will list the available chimes to play with information on each chime
CHMU name
Play the chime by giving its name, quotes and file extension are not used
example:
chmu strk12
CON?
CONstants command help message
CONG
Will return the value in decimal and hexadecimal of a known constant
example:
cong red
will reply:
red = 16711680 0xff0000
CONL
Reload constants file
CONR
Will report the number of constants known and the memory used (heap) to hold
them
DAT?
DATe command help message
Page 51
Version 1.0
Copyright Grahame Marsh/Nick Stock 2019
Содержание An E1T Timepiece
Страница 79: ...Fortress How It Works Board Schematics and Function Page 79 Version 1 0 Copyright Grahame Marsh Nick Stock 2019...
Страница 82: ...Page 82 Version 1 0 Copyright Grahame Marsh Nick Stock 2019 1 1 SAM3X8C schematic...
Страница 108: ...Page 108 Version 1 0 Copyright Grahame Marsh Nick Stock 2019...
Страница 109: ...Page 109 Version 1 0 Copyright Grahame Marsh Nick Stock 2019...
Страница 110: ...Page 110 Version 1 0 Copyright Grahame Marsh Nick Stock 2019...
Страница 120: ...E1T Data Sheet Page 120 Version 1 0 Copyright Grahame Marsh Nick Stock 2019...