Содержание V-GPS-TX

Страница 1: ...Valcom Master Clock V2 V WMCA V GPSA V GPS TX Valcom Inc 5614 Hollins Road Roanoke VA 24019 ...

Страница 2: ... Output Setting Clock 2 Relay Output Setting the Primary Input Setting the Secondary Input Setting the Offset Setting the Bias Seconds Setting Once a Day Pulse Input Sending Diagnostics Sync Wire Protocol Definitions Web Browser Programming Log In Main Menu Technician Level System Settings IP Settings Clock Features Database Maintenance Support Frequently Asked Questions Troubleshooting Page 3 Pag...

Страница 3: ...t at the designated markings from step 1 4 Install the four anchors in the holes that were just drilled 5 Install the first two screws in the top holes leaving 1 8 of the thread exposed 6 Line up the top key slots over the screws and lock the master clock into place 7 Install the bottom screws through the wiring access panel and tighten into place 8 After all wiring is complete re install the wiri...

Страница 4: ...232 port is used for debugging only Power Input This power outlet is used to power up the Valcom master clock 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 9 10 Installing the Master Clock with the Line Cord Receptacle 10 GPS Antenna This port is for connecting the GPS Antenna V GPSA or V GPS TX only 8 Caution Do not plug in the power cord until the following steps are completed 1 The square knockout on the wir...

Страница 5: ...nnections Wired Systems 2 Wire Communication V CCU V C6124P 24 volt outputs 24 VDC IN DATA IN 19 18 2 Wire Digital Output to Clocks V D2425 or V D2440 V A2412 or V A2416 Orange Yellow Black White V C6124P and the V CCU are ordered as a V VCU ...

Страница 6: ...Valcom Master Clock V2 Page 6 System Connections Wired Systems Sync Wire Communication via Clock 1 or 2 10 Amp Contact Rating ...

Страница 7: ... Hot 24VAC Neutral 24VAC Hot N O COM This system can accommodate both a primary and secondary for backup auxiliary time synchronization input The following protocols cannot be used simultaneously 59 minute sync 58 minute 1 4 sync National Time Rauland Dukane Digital Rauland Digital and once a day Pulse An example of a configuration would be SNTP being the primary input and 58 minute correction bei...

Страница 8: ...uts Sync Wire Inputs Installation National Time Rauland Rauland Digital Dry Contact Closure 110VAC Interface 24VAC Interface 7 17 8 12 16 17 15 17 110VAC Neutral 110VAC Hot 24VAC Neutral 24VAC Hot N O COM 11 17 Dig Line 5V Input Output ...

Страница 9: ...Valcom Master Clock V2 Page 9 Inputs Sync Wire Inputs Installation Dukane Digital Once a Day Pulse Dry Contact Closure 7 17 8 12 N O COM 7 17 14 8 Minute Pulse Ground 13 Reset ...

Страница 10: ...0 Patch Cable Installation Wall Jack to Network Fig 1 1 1 Connect a patch cable to the RJ45 port on the Valcom Master Clock as shown in Fig 1 1 2 Connect the other end of the patch cable to an Ethernet jack connected to the network ...

Страница 11: ...r on the left side of the LED display This prompt allows the user to set the month Use the bottom button to scroll between 01 12 Programming the Valcom Master Clock Press both buttons on the front panel simultaneously to enter programming mode Setting the Time from the LED Display To set the time press the top button to change the hour and or the bottom button the set the minute See Fig 2 1 Set Ho...

Страница 12: ...ery hour Press the top button to enter option 12 The num ber 12 will appear on the left side of the LED display This option allows the user to enable or disable Daylight Savings Time Press the bottom button to scroll between d 1 or 2 d will disable this option 1 will enable daylight savings pre 2007 2 will enable daylight savings post 2007 Press the top button to enter option 3 The number 3 will a...

Страница 13: ... side of the LED display This option allows the user to set the min utes at which the relay will close Press the bottom button to scroll through 00 59 Press the top button to enter option 20 The num ber 20 will appear on the left side of the LED display This option allows the user to program Clock 1 Press the bottom button to scroll through 1 2 3 4 5 6 7 8 9 Please refer to relay selection mode on...

Страница 14: ... on the left side of the LED display This option allows the user to set the hour at which the relay will close Press the bottom button to scroll through 00 23 Press the top button to enter option 23 The num ber 23 will appear on the left side of the LED display This option allows the user to set the sec onds at which the relay will close Press the bottom button to scroll through 00 59 Press the to...

Страница 15: ...P 02 59 Minute Correction 03 58 Minute Correction 1 04 58 Minute Correction 2 05 58 Minute Correction 3 06 58 Minute Correction 4 07 National Time Rauland 08 Dukane 09 Rauland Digital 10 Wireless Repeater 11 Once a Day Pulse 12 GPS 13 RS485 Selecting this allows access to options 34 36 Press the top button to enter option 27 The num ber 27 will appear on the left side of the LED display This optio...

Страница 16: ...set to 11 Press the top button to enter option 31 The number 31 will appear on the left side of the LED display This option allows the user to select the secondary auxiliary input Press the bottom button to scroll between 1 13 to select the input Press the top button to enter option 32 The num ber 32 will appear on the left side of the LED display This option allows the user to set the offset of t...

Страница 17: ... A 00 will appear on the right side if it is not receiving an Internet Connec tion This option is a read only option Press the top button to enter option 35 The num ber 35 will appear on the left side of the LED display This option allows the user to set the min utes that the time is to go to when Once A Day Pulse is selected Press the bottom button to scroll through 00 59 This option is only avai...

Страница 18: ...ess the bottom button to scroll be tween E d Setting the option to E will enable the option and will enter diagnostic mode Setting the option to d will disable the option and upon depressing the top button the clock will return to the time Press the top button to enter option 51 The num ber 51 will appear on the left side of the LED display This option allows the user to send the diagnostic to the...

Страница 19: ...5 47 05 5 59th minute The hourly correction for 8 seconds every hour from XX 57 54 to XX 58 02 The daily correction 5 a m 5 p m is a 14 second pulse from 5 57 54 to 5 58 08 6 National Time Rauland_1 The hourly correction is for 25 seconds every hour from XX 00 00 to XX 00 25 The daily correction 6 a m 6 p m is 25 seconds on 35 seconds off every minute for 24 minutes 7 National Time Rauland_2 The h...

Страница 20: ...g and editing events and schedule changes The default password for the user level is 1111 It can be changed in the technician level The technician level password is 6063 and gives you full access to all of the enabled features of the master clock Log In This button when pressed will attempt to log in to the master clock with the password that was entered in the field above Forgot Password This but...

Страница 21: ...tered in 24 hour format HH MM SS After typing in the desired time click the Submit button to set the time on the unit if there is no input connected Date This field is where the current date is displayed The date can be edited by clicking within the field and typing in the desired date The date must be entered in mm dd yyyy format After typing in the desired time click the Sub mit button to set th...

Страница 22: ...r 24 hour mode enabling or disabling Daylight Savings Time and editing the standard durations for each zone Database Maintenance This link when clicked will bring the user to the Database Maintenance section This is where all of the events and schedules can be saved and backed up Saved events and schedules can also be downloaded in this section Web Browser Programming Technician Level Menu 1 2 3 4...

Страница 23: ...Valcom Master Clock V2 Page 23 Web Browser Programming System Settings Page 1 1 2 3 4 5 6 7 ...

Страница 24: ...GMT Offset This field sets the positive or negative offset for GMT time For instance eastern time zone is a nega tive five hour offset See Fig 3 1 for typical offsets Submit This button when pressed will save any changes made on the page Cancel This button when pressed will clear out any fields and not save any data Menu This button when pressed will bring the user back to the main menu 1 2 3 4 5 ...

Страница 25: ...Valcom Master Clock V2 Page 25 System Settings Page 2 Web Browser Programming 1 2 3 4 5 6 7 8 ...

Страница 26: ...d Digital and once a day Pulse An example of a configuration would be SNTP being the primary input and 58 minute correction being a secondary input Setting the primary source to 59 minute sync and the secondary source to Dukane digital would be an incorrect configuration Clock 1 Circuit This drop down list allows the user to select the sync wire output for the Clock 1 circuit The choices are 59 Mi...

Страница 27: ...Valcom Master Clock V2 Page 27 IP Settings Page 1 Web Browser Programming 1 2 3 4 5 6 7 8 9 ...

Страница 28: ...n may be needed for certain networks IP Address This field allows the user to set the IP address for the device DHCP This drop down list allows the user to turn DHCP on or off DHCP allows the master clock to look for an IP address on its own if the network has a DHCP server Device Name This field allows the user to name the device a unique name Submit This button when pressed will save all of the ...

Страница 29: ...y which NTP servers that the master clock will try to acquire time from Submit This button when pressed will save all of the information to the master clock Cancel This button when pressed will clear out any changes made and will not save any data Menu This button when pressed will bring the user back to the main menu 1 2 4 5 6 1 2 4 5 6 3 Rotate Servers This checkbox when checked allows the maste...

Страница 30: ...the master clock IP Address This display the IP address for the master clock Device Name This displays the device name for the master clock Menu This button when pressed will bring the user back to the main menu 1 2 3 4 5 1 2 3 4 5 Paid Provisioned Features This displays the options that are enabled on your device GPS SNTP Client ...

Страница 31: ... option they want The option can be disabled pre 2007 and post 2007 Pre 2007 has the old style daylight savings time format that was enacted prior to 2007 Post 2007 daylight savings time is the current newer format that is followed today Submit This button when pressed will save all of the information to the master clock Cancel This button when pressed will clear out any changes made and will not ...

Страница 32: ... for backup purposes Choose File This button when pressed will allow the user to browse for the saved db file that contains the saved events and schedules Download This button when pressed will download the selected file and reset the master clock with those events and schedules already configured Menu This button when pressed will bring the user back to the main menu 1 2 3 4 1 2 3 4 ...

Страница 33: ...er through a cross over cable Yes the Valcom Master Clock can be accessed through a cross over cable or via a LAN connection What is the maximum length I can go with the GPS cable When the GPS option is purchased a 75 foot cable comes standard with the unit This is Valcom s recom mended longest distance What inputs can the Valcom Master Clock accept The Valcom Master Clock can accept an input from...

Страница 34: ...n an unobstructed area that is in complete view of the sky Also check to make sure the connections on each end of the cable are securely tightened Lastly verify that there are no kinks or breaks in the supplied GPS cable My sync wire system doesn t seem to be getting the correct time What should I do The clock 1 and clock 2 outputs control the sync wire systems Verify that the correct system is se...