Install the AP433e
31
To mount an AP433e above the ceiling with the optional T-bar kit, follow these steps:
1.
Determine the location on the ceiling rails where the AP will be mounted and remove the
ceiling tile.
2.
Unpack the T-bar hanger kit.
3.
Unlock the AP by sliding the locking key into the small hole with an unlocked image above
it.
Figure 12:
Ports and Unlock Mechanism for the AP433e
4.
Attach the square bracket to the underside of the main support bar using the screws pro-
vided, as shown in
Any Fast Ethernet (FE) cables installed in air-handling spaces should be suitable under NEC Article
800.50 and marked accordingly for use in plenums and air-handling spaces with regard to smoke prop-
agation, such as CL2-P, CL3-P, MPP (Multi Purpose Plenum), or CMP (Communications Plenum). Use
Ethernet cable that meets the requirements for operating in plenums and environmental air space in
accordance with Section 300-22(C) of the NEC.