Troubleshooting and Error Conditions
When the system encounters an error condition the ACTIVE LED and BLAST LED will alternately
flash RED to indicate that an error was detected. The information related to the error will be
indicated using the numbers around the SPREADER dial by illuminating the number of the error.
The following table can be used to determine the active error, what conditions caused it to occur
and any recommended actions that can be taken to resolve the error.
Pressing the liquid dial will acknowledge the error condition and either advance the indicator to
the next error condition or if no more errors are active place the system into normal operation
mode. Stuck input errors and the valve power error cannot be acknowledged and will remain
active until resolved.
System Status
Condition
Recommended Action
Unstable Voltage Detected
The system is detecting an unstable
voltage input on the constant power
wire during startup.
Verify that the voltage input for
the constant power connection
is stable and above 8 volts.
Stuck Spreader Knob
The green SPREADER knob was
pressed during startup.
Verify that the green
SPREADER knob is not
pressed. This error condition
cannot be acknowledged and
will remain active until cleared.
Stuck Spinner Knob
The blue SPINNER knob was pressed
during startup.
Verify that the blue SPINNER
knob is not pressed. This error
condition cannot be
acknowledged and will remain
active until cleared.
Stuck Liquid Knob
The gray LIQUID knob was pressed
during startup.
Verify that the gray LIQUID
knob is not pressed. This error
condition cannot be
acknowledged and will remain
active until cleared.