SSC3100 Operation & Calibration Manual
Description of Calibration Values
14
The liquid output will run independent of the
granular output allowing the liquid to be active
when the granular rate is 0. In this mode the
liquid output will not change when the blast
feature is active.
5
Direct (Liquid Output Blasts)
The liquid output will run independent of the
granular output allowing the liquid to be active
when the granular rate is 0. In this mode the
liquid output will increase to the max setting
when blast is active.
Aux Output Configuration
The Aux Output Configuration will determine the operation of the output
associated with the loose wire labeled AUX in the harness. The setting is
indicated by having the liquid dial illuminated at 9. The value is indicated
by the numbers around the spreader dial and the table below. The default
value is None.
Spreader
Dial
Description
0
None/Off
The aux output does nothing and will be off.
1
Auger On
The aux output will be on when the auger is
running.
2
Liquid On
The aux output will be on when the liquid output
is active.
Restore Defaults
The Restore Defaults item allows for the resetting of all calibration settings
to factory default settings. The setting is indicated by having the 0 and 10
illuminated around the liquid dial.
To restore the calibration settings, press and release the spreader dial then
press and release the spinner dial.
Firmware Version
The firmware version item allows for the determination of the systems
firmware (software) version. The setting is indicated by having the 1 and
10 illuminated around the liquid dial.
The number indicated by the spreader dial indicates the major number and
the number indicated by the spinner dial indicates the minor number.
(Version = Major Number
.
Minor Number)