SSC6100 Operation Manual
Applying Material - Blast
6
Blast
Blast is a spreader feature that runs the applicable output at the maximum percentage for a set
amount of time. By default, Blast is set to spread for ten seconds.
When Blast is activated, the BLAST LED will illuminate RED.
To activate Blast:
STEP 1:
Press the Blue SPINNER Knob on the Operator Interface. The system will blast
for its configured amount of time. The Blast feature works whether or not the
system is in standby or the vehicle is moving.
To deactivate Blast before it automatically shuts off:
STEP 1:
While the system is Blasting, press the Blue SPINNER Knob on the Operator
Interface. The Blast feature will shut off and return to its previous operation
(spreading or standby).
To reduce the risk of death or injury, ensure
that all personnel are clear from moving
machinery before activating outputs.
When blast mode is activated, blast rates will
only be applied to outputs with application rates
currently not set to zero.
NOTE: Blast mode does not affect the spinner
output.