
190
29. Network Settings
29-1. Arcnet
Connecting HVS-35OU/35ROU to the Main Unit (HVS-350HS)
For the main unit (hereafter called MU), HVS-35OU and HVS-35ROU (hereafter called OU
for both) to communicate, use the BNC cable to connect an Arcnet port on each unit. If you
want to connect other devices to the Arcnet, use the other Arcnet port of the switcher or the
control panel. If either or both of them are the last devices in the network, the other port has to
be 75 ohm-terminated. Refer to section 3-3. "How to Connect between MU and OU" for
details.
ARCNET Menu
The factory default settings for the ARCNET are shown in the table below. Change ARCNET
settings only when necessary. The settings can be made in the [SETUP-SYSTEM- ARCNET]
menu.
SYSTEM : OU ID :OU NO :CTRL MU : MU ID : 1/2
ARCNET : = 1 :=OU1 : =250 : =250 :
SYSTEM : MU ID : : 2/2
ARCNET : = 250 : :
Item
Description
Default setting Setting range
OU ID
Sets Arcnet ID for the OU.
1
1-255
CTRL MU Selects Arcnet ID of the MU controlled by the OU. 250
1-255
MU ID
Sets Arcnet ID for the MU.
250
1-255
If you are configuring one MU and OU each via ARCNET, connect them by using the BNC
connectors and leave them to their factory default-set ID numbers (250 and 1 respectively).
Turning F2 displays the accessible MU ID(s) under
CTRL MU ID
in the menu. Select an MU
to be controlled. If you want to disconnect the MU from the OU on the Arcnet, select --- under
CTRL MU ID
.
Changing the MU ID
If you want to change the MU ID, connect the MU to the OU and disconnect other devices
from the network. Power on both MU and OU and change the MU ID. Turn the power of all
units off, re-connect the units in the system, and turn the system power back on to
re-configure the network. Note that the new ID will not be valid until the units are powered ON
again.
Notes on Network Configuration
75-ohm BNC cables (5C2V equivalent or higher) are required for ARCNET connection
ARCNET is configured as a simple Bus topology network. BNC terminators equipped with a
75-ohm resistor should be installed on both ends of a bus network segment.
Total network cable length should be less than 100 m. If more than 100 m is required, use
ARCNET hubs (up to 2).
Minimum distance between ARCNET devices is 1 m.
To connect 8 or more ARCNET devices in a nework, use an ARNCET hub.
Please consult your FOR-A reseller for more information.
Adding ARCNET devices to the Arcnet LAN
If you want to connect other ARCNET devices to the MU and the OU, additional connection
cables are required and the network should be reconfigured again. Consult your FOR-A
resellers for more details.
Содержание HVS-350HS
Страница 1: ...HVS 350HS Digital Video Switcher HVS 35OU HVS 35ROU Operation Unit 4th Edition Rev 1 OPERATION MANUAL ...
Страница 224: ......
Страница 227: ...Appendix 3 1 HVS 30OU for HVS 350HS Operation Unit 1st Edition APPENDIX 3 ...
Страница 258: ......