Operating Manual EMGZ622A/642A
17
8.5
Mathematical Method
If the material tension cannot be simulated, calibration has to be done by calculation. This
way of calibrating is less accurate because the exact angles are often unknown and the
effective mounting conditions, which usually deviate from the ideal, are not taken into
account.
•
Offset adjustment is done as written under „Simulating method“.
•
The Gain value will be calculated by the following formula and then inputted in the
parameter
Gain
(refer to „9.5 Description of the parameters: EMGZ622A/642A“).
fig. 12: Force vectors in the FMS force measuring bearing
C431012e
Definition of symbols:
α
angle between vertical and measuring
web axis
F
B
material
tension
β
angle between vertical and F
M
F
G
roller
weight
γ
wrap angle of material
F
M
measuring force resulting from F
B
γ
1
entry angle of material
F
Meff
effective measuring force
γ
2
exit angle of material
n
number of force sensors
δ
Angle between measuring web axis and F
M
(
)
n
ck
GainFeedba
⋅
⋅
=
2
/
sin
sin
1
γ
δ