Operating Manual EMGZ622A/642A
30
12.4
Configuration
The configuration defines how many process data (byte and word) are exchanged during the
cyclic communication between control system and measuring amplifier.
Several modules enable a flexible use of the measuring amplifier. In a single measuring
amplifier only one module can be set active at the time.
Module 1: Basic telegram
4 bytes (2 word) are transmitted from the control system to the measuring amplifier and also 4
bytes (2 word) from the measuring amplifier to the control system in each data cycle.
Byte 0
Byte 1
Byte 2
Byte 3
Request telegram
(master
→
slave)
Function code Measuring point
Empty
Empty
Response telegram
(slave
→
master)
Function code Measuring point
Data (higher
byte)
Data (lower byte)
Module 2: Reserved
Module 3: Basic telegram and 4 word operation value
The measuring amplifier responses with 4 bytes of the basic telegram and the 4 word.
Byte 0
Byte 1
Byte 2
Byte 3
request telegram
(master
→
slave)
Function code Measuring point
Empty
Empty
response telegram
(slave
→
master)
Function code Measuring point
Data (higher
byte)
Data (lower byte)
EMGZ622
EMGZ642
Word 0
Word 1
Word 2
Word 3
Measuring point
Range A
(HB)/(LB)
Measuring point
Range B
(HB)/(LB)
Measuring point
Range A
(HB)/(LB)
Measuring point
Range B
(HB)/(LB)
Module 4: Reserved
12.5
Function Code
Master
→
Slave
Function Values
Value
Meaning
Remarks
01h
Range A
Lower measuring range
02h
Range B
Higher measuring range
05h
A/D-value gross range A
A/D-value amplifier lower measuring range
06h
A/D-value gross range B
A/D-value amplifier higher measuring range
The measuring amplifier responses with the response telegram.
Содержание EMGZ622A
Страница 8: ...Operating Manual EMGZ622A 642A 8 6 Dimensions fig 3 Dimensions E611002e...
Страница 26: ...Operating Manual EMGZ622A 642A 26 10 Serial Interface RS232 Optional...
Страница 28: ...Operating Manual EMGZ622A 642A 28...
Страница 31: ...Operating Manual EMGZ622A 642A 31 13 Interface CAN Bus Optional...
Страница 32: ...Operating Manual EMGZ622A 642A 32 14 Interface DeviceNet Optional...