3.   Place the blower against the lower rear 

wall  of  the  firebox  outer  wrapper  with 

the exhaust port directed upward. Attach 

Thermal disc magnetic bracket to the bot-

tom of the firebox sub-floor. The thermo

-

disc must be oriented near the fireplace 

bottom as shown in Figure 28, in order to 

sense temperature and properly operate. 

The blower will be held in position against 

the back wall by the magnets incorporated 

onto the blower housing (see Figure 28).

4.   Be certain that all wire terminals are 

securely attached to terminals on blower 

motor and that the screw retaining the 

green ground wire is tight. 

5.   Mount the speed control box against the 

mounting plate provided in the lower fire

-

place cavity by placing the plastic control 

shaft forward through the round hole (see 

Figure 26, page 20).

6.  While supporting speed control, secure 

control shaft with lock nut by pushing and 

turning lock nut with pliers clockwise until 

it is tight against mounting plate. Place 

control knob provided on shaft (see Figure 

26, page 20).

7.   Check to make sure that the power cord is 

completely clear of the blower wheel and 

that there are no other foreign objects in 

blower wheel. Also double check all wire 

leads and make sure wire routing is not 

pinched or in a precarious position. Correct 

accordingly. 

8.  Turn on power to duplex outlet if previ-

ously turned off per the warning in column 

2, page 19.

9.   Plug in blower power cord to duplex outlet.
10. The blower will only run when the speed 

control knob is in the ON position and 

the thermal switch senses temperature 

after the fireplace begins to heat up. The 

blower speed can be adjusted by rotating 

the control knob. To turn off, turn knob fully 

counterclockwise until it clicks off. If the 

blower is ON and has been running with the 

fireplace operating, the blower will continue 

to run for a short time after the fireplace has 

been turned off. As the thermal switch cools 

down, the blower shuts down automatically.

11.  Peel off the backing paper and stick the 

supplied wiring diagram decal on the 

firebox bottom approximately 12" in front 

of the blower (see Figure 27, page 20).

FIREPLACE INSTALLATION

Continued

Figure 28 - Blower Model BKT

Figure 29 - Blower Wiring Diagram for 

Thermostat-Controlled Models 

Blower Wiring Diagram

  CAUTION:  Label  all  wires 

prior  to  disconnection  when 

servicing controls. Wiring errors 

can  cause  improper  and  dan

-

gerous operation. Verify proper 

operation after servicing. 

Blue

Variable

Fan Switch

Fan Switch

(N.O.)

Green

White

On

110/115 

V.A.C.

Blower

Motor

Black 

Off

1

2

Black

Thermodisc

Route BKT Blower 

Through This Area

Side View Firebox Bottom

Ring Terminal 

on Green Wire

Magnetic 

Strips

Blower 

Location

Magnets

Air Flow 

Direction

Jumper 

Wire

To Blower 

Motor Terminal 

Thermal 

Disc 

Magnetic 

Bracket 

Assembly

To 

Thermal 

Switch

Air Flow 

Direction

Phillips 

Screw

Power Cord

Содержание T32EN-A Series

Страница 1: ...asoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use...

Страница 2: ...ently located manufactured mobile home where not prohib ited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use...

Страница 3: ...he influence of alcohol and those at high altitudes Natural and Propane LP Gas Natural and propane LP gases are odorless An odor making agent is added to the gas The odor helps you detect a gas leak H...

Страница 4: ...cing installing or repairing Only a qualified service person should install service or repair this fireplace Have fire place inspected annually by a qualified service person 7 You must keep control co...

Страница 5: ...nt through the roof vertical or it may vent to an outside exterior wall hori zontal The vent pipe installation is very important to allow for proper operation You must follow the venting instructions...

Страница 6: ...p of yourfireplace exceptwherestandoffspacers are integrally attached If standoff spacers are attached to your fireplace these spacers can be placed directly against wall or framing material See frami...

Страница 7: ...ental heat Use this fireplace along with your primary heating sys tem Do not install this fireplace as your primary heat source If you have a central heating system you may run system s circulating bl...

Страница 8: ...0 000 and 50 000 12 30 cm in Canada if between 10 000 and 100 000 12 30 cm in US if greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In Canad...

Страница 9: ...ctly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than 1 2 in size GAS VENT DIRECTLY BELOW KEE...

Страница 10: ...bowing or offsetting Always use wall firestops when penetrating walls and firestops when penetrating ceil ings or attic spaces If using a venting configuration of only horizontal venting with no verti...

Страница 11: ...d twist one section clockwise approximately one quarter turn until the sections are fully locked see Figure 8 Note Horizontal runs of vent must be supported every three feet Use wall straps for this p...

Страница 12: ...terior fascia material 7 Combustible Exterior Wall Only Slide the wall firestop over the vent pipe before connecting horizontal run to vent cap see Figure 12 8 Carefully move fireplace with vent as se...

Страница 13: ...NT If using a venting configuration of only horizontal venting with no vertical run a 1 4 rise for every 12 of run toward the termina tion is required WARNING Never run vent downward as this may cause...

Страница 14: ...loor installation where pipe vents horizontally through wall over 12 horizontal pipe Basement installation where one foot clearance from ground to termination is possible SNORKEL TERMINATION INSTALLAT...

Страница 15: ...iguration for Venting Using Two 90 Elbows Venting with Two 90 Elbows Horizontal H1 Vertical V Horizontal H1 Horizontal H2 5 min 2 max 6 max 6 min 4 max 12 max 7 min 6 max 18 max 8 min 8 max 20 max 20...

Страница 16: ...earance space If the area above the ceiling is a living space install firestop below the framed hole The firestop should be installed with no less than three nails per side see Figure 20 2 Assemble th...

Страница 17: ...Figures 21 through 24 show four different configurations for vertical termination VENTING INSTALLATION INSTRUCTIONS Continued Figure 21 Vertical Venting Configuration Using Two 90 Elbows with Two Hori...

Страница 18: ...NENTS FMI PRODUCTS LLC 5 8 Pipe Vent Kits Number Description P58 6 6 Section Double Wall Pipe Galvanized P58 12 12 Section Double Wall Pipe Galvanized P58 24 24 Section Double Wall Pipe Galvanized P58...

Страница 19: ...LLATION CHECK GAS TYPE Use proper gas type for the fireplace unit you are installing If your gas supply is not correct do not install fireplace See retailer where you purchased the fireplace for prope...

Страница 20: ...are no other foreign objects in blower wheel Turn blower on and check for operation Turn blower off by turning knob fully counterclockwise before continuing 10 Peel off the backing paper and stick the...

Страница 21: ...ower to duplex outlet if previ ously turned off per the warning in column 2 page 19 9 Plug in blower power cord to duplex outlet 10 The blower will only run when the speed control knob is in the ON po...

Страница 22: ...as pressure to between 11 and 14 inches of water If you do not reduce incoming gas pressure fire place regulator damage could occur Install external regulator with the vent pointing down as shown in F...

Страница 23: ...ccess holes on side of fireplace 3 Attach flexible gas line from gas supply to control valve see Figure 32 4 Check all gas connections for leaks See Checking Gas Connections FIREPLACE INSTALLATION Con...

Страница 24: ...gas fireplace 3 Make sure control knob of fireplace is in the OFF position 4 Check all joints from equipment shutoff valve to gas valve see Figure 34 or Figure 35 Apply noncorrosive leak detection fl...

Страница 25: ...bondoorandpushing down and back on latch see Figure 38 6 Replace screen rod assembly by revers ing step 1 7 Replace louvers by reversing procedure under Removing Louver Panels for T32 series 8 Replace...

Страница 26: ...brick panel by sliding it between the grate and the side of the firebox see Figure 40 7 Install the right brick panel using the same method described Figure 39 Installing Rear Brick Panel Rear Brick...

Страница 27: ...ce log 4 right log onto the landing on right side of front log as shown in Figure 44 5 6 Metal Pins Rear Log 7 Place lava rock along sides and front of firebox bottom in areas that are visible only It...

Страница 28: ...eless hand held re mote control the wall switch must be in the ON position to be operational The remote control then becomes the switching mechanism for fireplace operation 1 Open lower louver panel 2...

Страница 29: ...lower louver panel OPERATING FIREPLACE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not fol low these instructions exactly a fire or explosion may result causing property damage per sonal in...

Страница 30: ...f the firebox and remove any dust dirt or other obstructions that will hinder the flow of air INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often PILOT ASSEMBLY The pilot asse...

Страница 31: ...CAUTION Do not vacuum if pieces are hot Use only the tempered glass door replace ment intended for this fireplace see Replace ment Parts page 35 for detail on ordering No substitutions may be made See...

Страница 32: ...ot open ing 7 No power to unit or the ignition module or power transformer is bad 8 Vent damper not fully open REMEDY 1 Check to see if you have gas supply and that equip ment shutoff valve is opened...

Страница 33: ...e blockage 1 Residues from manufac turing processes and logs curing 1 Metal expanding while heating or contracting while cooling REMEDY 1 Check wiring connection Refer to wiring diagram see Wiring Dia...

Страница 34: ...t the flame does not exces sively impinge on it 2 Inspect the opening at the base of the burner to see that it is NOTpacked with any type of material 1 Properly locate logs see log placement section o...

Страница 35: ...arranty Contact authorized retailers of this product If they can not supply original replacement part s call FMI PRODUCTS LLC s Techni cal Service Department at 1 866 328 4537 When calling have ready...

Страница 36: ...6 ILLUSTRATED PARTS BREAKDOWN MODELS V T32E N P A V T32E NB PB A V T32E NR PR A V T32ENRB A V T32EPRB A V TC32E N P AND V TC32E NB PB 6 7 21 18 19 10 13 2 12 20 8 22 2 22 6 22 4 22 5 22 3 22 1 1 14 9...

Страница 37: ...3 Heat Shield 1 12 108897 01 108897 01 Rear Refractory Brick Panel B Models Only 1 13 108901 01 108901 01 Right Refractory Brick Panel B Models Only 1 14 108901 02 108901 02 Left Refractory Brick Pane...

Страница 38: ...P V M V T R TH M V 21 23 24 26 25 27 17 22 16 14 20 12 9 8 10 13 15 19 18 28 29 11 2 1 7 3 5 4 6 ILLUSTRATED PARTS BREAKDOWN BURNER ASSEMBLY MODELS V T32E N P A V T32E NB PB A V T32E NR PR A V T32ENR...

Страница 39: ...25 Orifice 47 Natural 1 14514 Orifice 55 Propane LP 1 16 14528 Brass Elbow Fitting 1 17 108863 01 Supply Connect Plug 1 18 23416 Electronic Components Board 1 19 14129 Transformer 1 20 11147 Screw 10...

Страница 40: ...ERSION KIT Not Shown PCDE 32T Propane LP Gas NCDE 32T Natural Gas FACE LOUVER PANEL KIT Not Shown RLD32 Rolled Black ROLLED LOUVER TRIM KIT Not Shown LT32B Brushed Brass LT32P Platinum DEFLECTION HOOD...

Страница 41: ..._____ _____________________________________________________ _____________________________________________________ _____________________________________________________ ________________________________...

Страница 42: ..._____ _____________________________________________________ _____________________________________________________ _____________________________________________________ ________________________________...

Страница 43: ..._____ _____________________________________________________ _____________________________________________________ _____________________________________________________ ________________________________...

Страница 44: ...originalfactoryreplacementparts Failuretouseoriginalfactoryreplacementpartsvoidsthiswarranty Travel handling transportation diagnostic material laborandincidentalcostsassociatedwithwarrantyrepairs unl...

Отзывы: