background image

www.fmiproducts.com

116647-01H

23

IMPORTANT:

 Install main gas valve (equip

-

ment shutoff valve) in an accessible location. 

The main gas valve is for turning on or shutting 

off the gas to the appliance.
Check your building codes for any special 

requirements for locating equipment shutoff 

valve to fireplaces.
Apply pipe joint sealant lightly to male NPT 

threads. This will prevent excess sealant from 

going into pipe. Excess sealant in pipe could 

result in clogged fireplace valves.

  WARNING:  Use  pipe  joint 

sealant that is resistant to liquid 

petroleum (LP) gas. 

We recommend that you install a sediment 

trap/drip leg in supply line as shown in Figure 

31, page 22. Locate sediment trap/drip leg 

where it is within reach for cleaning. Install 

in piping system between fuel supply and 

fireplace. Locate sediment trap/drip leg where 

trapped matter is not likely to freeze. A sedi-

ment trap traps moisture and contaminants. 

This  keeps  them  from  going  into  fireplace 

gas controls. If sediment trap/drip leg is not 

installed or is installed wrong, fireplace may 

not run properly.

CONNECTING FIREPLACE TO GAS 

SUPPLY

Installation Items Needed

•  5/16" hex socket wrench or nut-driver
•  sealant (resistant to propane/LP gas, not 

provided)

1.  Open lower louver door panel by gen-

tly pulling forward.

2.  Route  flexible  gas  line  (provided  by 

installer) from equipment shutoff valve 

to fireplace. Route flexible gas supply 

line through one of the access holes 

on side of fireplace.

3.  Attach flexible gas line from gas supply 

to control valve (see Figure 32).

4.  Check all gas connections for leaks. 

See 

Checking Gas Connections

.

FIREPLACE 

INSTALLATION

Continued

Figure 32 - Connecting Flexible Gas Line 

to Electronic Valve

1/2" NPT 

Incoming Gas 

Line

Inlet 

Pressure 

Tap

Outlet 

Pressure 

Tap

Equipment 

Shutoff 

Valve

Flexible Gas 

Line Do NOT 

Kink

Note:

 Wire Connections Not Shown for Clarity

Red Surface 

Indicates For 

Propane/LP 

Use Only

CHECKING GAS CONNECTIONS

 WARNING: Test all gas piping 

and connections, internal and 

external to unit, for leaks after 

installing or servicing. Correct 

all leaks at once.

 WARNING: Never use an open 

flame to check for a leak. Apply 

noncorrosive leak detection fluid 

to all joints. Bubbles forming show 

a leak. Correct all leaks at once.

PRESSURE TESTING GAS SUPPLY 

PIPING SYSTEM 
Test Pressures In Excess Of 1/2 PSIG 

(3.5 kPa)

1.  Disconnect fireplace and its individual 

equipment shutoff valve from gas supply 

piping system. Pressures in excess of 1/2 

psig (3.5 kPa) will damage fireplace gas 

regulator.

2.  Cap off open end of gas pipe where equip-

ment shutoff valve was connected.

3.  Pressurize supply piping system by either 

opening propane/LP supply tank valve for 

propane/LP gas fireplace or opening main 

gas valve located on or near gas meter for 

natural gas fireplace or using compressed 

air.

4.  Check all joints of gas supply piping sys

-

tem. Apply noncorrosive leak detection 

fluid to all joints. Bubbles forming show a 

leak. Correct all leaks at once.

5.  Reconnect fireplace and equipment 

shutoff valve to gas supply. Check recon-

nected fittings for leaks. 

Содержание T32EN-A Series

Страница 1: ...asoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use...

Страница 2: ...ently located manufactured mobile home where not prohib ited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use...

Страница 3: ...he influence of alcohol and those at high altitudes Natural and Propane LP Gas Natural and propane LP gases are odorless An odor making agent is added to the gas The odor helps you detect a gas leak H...

Страница 4: ...cing installing or repairing Only a qualified service person should install service or repair this fireplace Have fire place inspected annually by a qualified service person 7 You must keep control co...

Страница 5: ...nt through the roof vertical or it may vent to an outside exterior wall hori zontal The vent pipe installation is very important to allow for proper operation You must follow the venting instructions...

Страница 6: ...p of yourfireplace exceptwherestandoffspacers are integrally attached If standoff spacers are attached to your fireplace these spacers can be placed directly against wall or framing material See frami...

Страница 7: ...ental heat Use this fireplace along with your primary heating sys tem Do not install this fireplace as your primary heat source If you have a central heating system you may run system s circulating bl...

Страница 8: ...0 000 and 50 000 12 30 cm in Canada if between 10 000 and 100 000 12 30 cm in US if greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In Canad...

Страница 9: ...ctly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than 1 2 in size GAS VENT DIRECTLY BELOW KEE...

Страница 10: ...bowing or offsetting Always use wall firestops when penetrating walls and firestops when penetrating ceil ings or attic spaces If using a venting configuration of only horizontal venting with no verti...

Страница 11: ...d twist one section clockwise approximately one quarter turn until the sections are fully locked see Figure 8 Note Horizontal runs of vent must be supported every three feet Use wall straps for this p...

Страница 12: ...terior fascia material 7 Combustible Exterior Wall Only Slide the wall firestop over the vent pipe before connecting horizontal run to vent cap see Figure 12 8 Carefully move fireplace with vent as se...

Страница 13: ...NT If using a venting configuration of only horizontal venting with no vertical run a 1 4 rise for every 12 of run toward the termina tion is required WARNING Never run vent downward as this may cause...

Страница 14: ...loor installation where pipe vents horizontally through wall over 12 horizontal pipe Basement installation where one foot clearance from ground to termination is possible SNORKEL TERMINATION INSTALLAT...

Страница 15: ...iguration for Venting Using Two 90 Elbows Venting with Two 90 Elbows Horizontal H1 Vertical V Horizontal H1 Horizontal H2 5 min 2 max 6 max 6 min 4 max 12 max 7 min 6 max 18 max 8 min 8 max 20 max 20...

Страница 16: ...earance space If the area above the ceiling is a living space install firestop below the framed hole The firestop should be installed with no less than three nails per side see Figure 20 2 Assemble th...

Страница 17: ...Figures 21 through 24 show four different configurations for vertical termination VENTING INSTALLATION INSTRUCTIONS Continued Figure 21 Vertical Venting Configuration Using Two 90 Elbows with Two Hori...

Страница 18: ...NENTS FMI PRODUCTS LLC 5 8 Pipe Vent Kits Number Description P58 6 6 Section Double Wall Pipe Galvanized P58 12 12 Section Double Wall Pipe Galvanized P58 24 24 Section Double Wall Pipe Galvanized P58...

Страница 19: ...LLATION CHECK GAS TYPE Use proper gas type for the fireplace unit you are installing If your gas supply is not correct do not install fireplace See retailer where you purchased the fireplace for prope...

Страница 20: ...are no other foreign objects in blower wheel Turn blower on and check for operation Turn blower off by turning knob fully counterclockwise before continuing 10 Peel off the backing paper and stick the...

Страница 21: ...ower to duplex outlet if previ ously turned off per the warning in column 2 page 19 9 Plug in blower power cord to duplex outlet 10 The blower will only run when the speed control knob is in the ON po...

Страница 22: ...as pressure to between 11 and 14 inches of water If you do not reduce incoming gas pressure fire place regulator damage could occur Install external regulator with the vent pointing down as shown in F...

Страница 23: ...ccess holes on side of fireplace 3 Attach flexible gas line from gas supply to control valve see Figure 32 4 Check all gas connections for leaks See Checking Gas Connections FIREPLACE INSTALLATION Con...

Страница 24: ...gas fireplace 3 Make sure control knob of fireplace is in the OFF position 4 Check all joints from equipment shutoff valve to gas valve see Figure 34 or Figure 35 Apply noncorrosive leak detection fl...

Страница 25: ...bondoorandpushing down and back on latch see Figure 38 6 Replace screen rod assembly by revers ing step 1 7 Replace louvers by reversing procedure under Removing Louver Panels for T32 series 8 Replace...

Страница 26: ...brick panel by sliding it between the grate and the side of the firebox see Figure 40 7 Install the right brick panel using the same method described Figure 39 Installing Rear Brick Panel Rear Brick...

Страница 27: ...ce log 4 right log onto the landing on right side of front log as shown in Figure 44 5 6 Metal Pins Rear Log 7 Place lava rock along sides and front of firebox bottom in areas that are visible only It...

Страница 28: ...eless hand held re mote control the wall switch must be in the ON position to be operational The remote control then becomes the switching mechanism for fireplace operation 1 Open lower louver panel 2...

Страница 29: ...lower louver panel OPERATING FIREPLACE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not fol low these instructions exactly a fire or explosion may result causing property damage per sonal in...

Страница 30: ...f the firebox and remove any dust dirt or other obstructions that will hinder the flow of air INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often PILOT ASSEMBLY The pilot asse...

Страница 31: ...CAUTION Do not vacuum if pieces are hot Use only the tempered glass door replace ment intended for this fireplace see Replace ment Parts page 35 for detail on ordering No substitutions may be made See...

Страница 32: ...ot open ing 7 No power to unit or the ignition module or power transformer is bad 8 Vent damper not fully open REMEDY 1 Check to see if you have gas supply and that equip ment shutoff valve is opened...

Страница 33: ...e blockage 1 Residues from manufac turing processes and logs curing 1 Metal expanding while heating or contracting while cooling REMEDY 1 Check wiring connection Refer to wiring diagram see Wiring Dia...

Страница 34: ...t the flame does not exces sively impinge on it 2 Inspect the opening at the base of the burner to see that it is NOTpacked with any type of material 1 Properly locate logs see log placement section o...

Страница 35: ...arranty Contact authorized retailers of this product If they can not supply original replacement part s call FMI PRODUCTS LLC s Techni cal Service Department at 1 866 328 4537 When calling have ready...

Страница 36: ...6 ILLUSTRATED PARTS BREAKDOWN MODELS V T32E N P A V T32E NB PB A V T32E NR PR A V T32ENRB A V T32EPRB A V TC32E N P AND V TC32E NB PB 6 7 21 18 19 10 13 2 12 20 8 22 2 22 6 22 4 22 5 22 3 22 1 1 14 9...

Страница 37: ...3 Heat Shield 1 12 108897 01 108897 01 Rear Refractory Brick Panel B Models Only 1 13 108901 01 108901 01 Right Refractory Brick Panel B Models Only 1 14 108901 02 108901 02 Left Refractory Brick Pane...

Страница 38: ...P V M V T R TH M V 21 23 24 26 25 27 17 22 16 14 20 12 9 8 10 13 15 19 18 28 29 11 2 1 7 3 5 4 6 ILLUSTRATED PARTS BREAKDOWN BURNER ASSEMBLY MODELS V T32E N P A V T32E NB PB A V T32E NR PR A V T32ENR...

Страница 39: ...25 Orifice 47 Natural 1 14514 Orifice 55 Propane LP 1 16 14528 Brass Elbow Fitting 1 17 108863 01 Supply Connect Plug 1 18 23416 Electronic Components Board 1 19 14129 Transformer 1 20 11147 Screw 10...

Страница 40: ...ERSION KIT Not Shown PCDE 32T Propane LP Gas NCDE 32T Natural Gas FACE LOUVER PANEL KIT Not Shown RLD32 Rolled Black ROLLED LOUVER TRIM KIT Not Shown LT32B Brushed Brass LT32P Platinum DEFLECTION HOOD...

Страница 41: ..._____ _____________________________________________________ _____________________________________________________ _____________________________________________________ ________________________________...

Страница 42: ..._____ _____________________________________________________ _____________________________________________________ _____________________________________________________ ________________________________...

Страница 43: ..._____ _____________________________________________________ _____________________________________________________ _____________________________________________________ ________________________________...

Страница 44: ...originalfactoryreplacementparts Failuretouseoriginalfactoryreplacementpartsvoidsthiswarranty Travel handling transportation diagnostic material laborandincidentalcostsassociatedwithwarrantyrepairs unl...

Отзывы: