background image

PARAGON FIRES 

 

PARAGON FOCUS RS PLUS 

      L.P.G Manual Version

  

ROOM SEALED INSET LIVE FUEL EFFECT GAS FIRE 

 

OWNER'S 

MANUAL 

 

 

Please read these instructions carefully before you start 

using the appliance 

 
 

Keep this booklet handy for future reference 

 

This appliance is  

for use in GREAT BRITAIN or 

 IRELAND only 

 
 
 
 
 
 

 
 
 

TELFORD 

SHROPSHIRE 

ENGLAND 

Summary of Contents for ROOM SEALED INSET LIVE FUEL EFFECT GAS FIRE

Page 1: ...SEALED INSET LIVE FUEL EFFECT GAS FIRE OWNER S MANUAL Please read these instructions carefully before you start using the appliance Keep this booklet handy for future reference This appliance is for u...

Page 2: ...neral Requirements 12 SECTION NINE Preparing the Appliance for Installation 13 SECTION TEN Install the appliance 14 Installing the Appliance into a Cavity Wall 14 Installing the Appliance into a Deep...

Page 3: ...aste These materials are not classified as hazardous waste and should be disposed of at a site licensed for the disposal of industrial waste The PARAGON FOCUS RS PLUS is an inset room sealed decorativ...

Page 4: ...ediately above first Run the fire on high over a few days The first time you light your new appliance a smell may occur due to its new condition This is quite normal and will soon disappear after a fe...

Page 5: ...SECTION THREE Operation Do not use this appliance without the glass panel fitted or if this panel is cracked or broken WARNING If the burner or pilot is extinguished for any reason do not attempt to...

Page 6: ...eading Supermarkets Remove the glass panel as follows Remove ash pan cover and fret Remove decorative trim held in place with four magnets Slacken but do not remove the 4 nuts securing the bottom glas...

Page 7: ...ADDED to the appliance If any Fuel Bed Parts are broken then they must be replaced before the appliance is used Note There is only a COAL fuel bed arrangement for the L P G Please check the label on t...

Page 8: ...g Fuel Bed Laying Continued COAL BED LAYOUT The Coal set as shown consists of Rear Matrix Front Matrix 10 x Individual Coals The Front Matrix is located as shown in front of the burner The Rear Matrix...

Page 9: ...ls as shown That completes the coal bed assembly Go to section eleven to complete the appliance assembly Ensure the glass panel and other associated parts are fitted before lighting the appliance SECT...

Page 10: ...ind decorative fret Note When flue length exceeds 200mm you may experience outing from cold In this case it may be necessary to remove the restrictor plate Please ensure that the flue pipe has been ad...

Page 11: ...D BRITISH STANDARDS B S 5871 PART 2 B S 5440 PART 1 B S 6891 B S 1945 Note This appliance must be installed to current versions of the above standards and include any relevant amendments THE BUILDING...

Page 12: ...as described in Section 10 GENERAL REQUIREMENTS The flue and air duct length must be between 100mm to 1metre The fire is supplied with a standard pipe length of 535mm to be cut in half to make a flue...

Page 13: ...ombustible surround should not be less than 800 mm provided fire is central to the surround and sides do not project more than 150 mm When vertical side forward projection is increased by 12 5 mm add...

Page 14: ...a horizontal line at a height of 555mm above the hearth line joining the two outside lines together Mark the position for a lintel above the top horizontal line Mark two short horizontal lines so they...

Page 15: ...so that it seals to both the flue pipe and the air duct use flue seal or fire cement to ensure air tight seal Drill through the four holes in the outer wall terminal plate and fix back to the wall usi...

Page 16: ...l taking account of the relative gas regulations appertaining to a gas pipe in a cavity Permanently fix the deep rebated surround in position and pack the void behind the fascia panel of the deep reba...

Page 17: ...200mm diameter must be fitted to these clearance holes To ensure that any condensation formed on the duct pipes does not drip on to the inner wall a length of galvanised wire must wrapped around each...

Page 18: ...closed in a gas tight sleeve It must be sealed at the point at which the sleeved installation pipe enters the fire The Gas Safety Installation and Use Regulations Certificate of exemption number 1 of...

Page 19: ...t up to the appliance conforming to the requirements referred to in section one of this manual SECTION THIRTEEN Instruct and Advise the Customer Demonstrate the lighting and extinguishing procedure to...

Page 20: ...ws on the left hand side 4 Disconnect the injector pipe from the left hand side of the gas control 5 Disconnect the pilot pipe from the underside of the pilot burner 9 Pull off the connection to the s...

Page 21: ...ness and re commission Replacement of the Pilot Injector 1 Undo the pilot tube nut at the pilot bracket 2 Pull the pipe gently back taking care not to damage 3 Remove the pilot injector from inside th...

Page 22: ...e must be installed by a GAS SAFE registered person 2 The appliance must be used in accordance with the users instructions 3 The appliance must be serviced annually by a GAS SAFE registered person 4 T...

Page 23: ...he helpdesk Model PARAGON FOCUS RS PLUS Serial No This information can be found on the label attached to the packaging and on the data badge which is located on the appliance remove decorative front f...

Page 24: ...First annual service Engineer Name Gas Safe Registration No Date of Second annual service Engineer Name Gas Safe Registration No Date of Third annual service Engineer Name Gas Safe Registration No Da...

Page 25: ...LT5944 Iss 1 25 10 11 25...

Page 26: ...AILS Name ________________________________ Address ________________________________ Post Code TELEPHONE No PRODUCT DETAILS Model PARAGON FOCUS RS PLUS Serial No Date of Purchase This information can b...

Page 27: ...LT5944 Iss 1 25 10 11 27...

Page 28: ...urner Tray Box Assembly Air Test Completed Microswitch Check Warning Label Fire Guard Nut Spinner Installation Seal 2090 Restrictor Elbow 2189 Magnets 4 x 3048 Glass Panel Canopy 4540 Flue Assembly Te...

Reviews: