INTRODUCTION
WARNING: This product con
-
tains and/or generates chemicals
known to the State of California
to cause cancer or birth defects
or other reproductive harm.
Model CD36M-LS and CD42M-LS is a heat
circulating gravity direct vent fireplace with
sealed combustion chamber. This fireplace
uses millivolt gas control valve and millivolt
ignition system.
This fireplace is convertible with the standard
setup as natural gas. Conversion may be per-
formed by the OEM mobile home builder or by
a qualified service person on-site. If you are
uncertain as to what gas your unit is equipped
for, please check the rating plate located in-
side of the appliance opening or consult your
mobile home supplier or your local distributor
of FMI PRODUCTS, LLC.
NOTICE: Check local building
codes for area requirements be
-
fore installing this appliance.
BEFORE YOU BEGIN
Before beginning the installation of your
appliance, read these instructions through
completely.
Figure 1 - Common Fireplace Locations
FULL
PROJECTION CORNER
INSTALLATION
FLUSH
INSTALLATION
To determine the safest and most efficient
location for your fireplace, consider the fol
-
lowing guidelines:
1. The location must allow for proper clear-
ances (see Figure 1).
• Flush installation is recommended where
living space is limited.
• Projected installation may be ideal for
a new addition to an existing finished
wall.
• Corner installation makes use of a space
that may not normally be used and pro-
vides a wider and more efficient range
for radiant heat transfer.
2. Consider a location where the fireplace
would not be affected by drafts, air con-
ditioning ducts, windows or doors.
3. A location that avoids the cutting of joists
or roof rafters makes ventilation installa-
tion easier.
This FMI PRODUCTS, LLC fireplace and its
components are safe when installed accord-
ing to this installation manual and operated as
recommended. Unless you use FMI PROD-
UCTS, LLC components designed and tested
for this fireplace system,
YOU MAY CAUSE
A SAFETY HAZARD!
The FMI PRODUCTS, LLC warranty will
be voided by, and FMI PRODUCTS, LLC
disclaims any responsibility for the following
actions:
A) Modification to the fireplace, components,
doors, blower, fans or vent system.
B) Use of any component part not manufac-
tured or approved by FMI PRODUCTS,
LLC in combination with a FMI PROD-
UCTS, LLC fireplace system.
Proper installation is the most important step
in ensuring safe and continuous operation
of the fireplace. Consult the local building
codes as to the particular requirements
concerned with the installation of all factory
built fireplaces. This fireplace, when installed,
must be electrically grounded in accordance
with local codes or in the absence of local
codes, with the
National Electrical Code,
ANSI/NFPA 70.
The installation must conform with local codes
or, in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1.
This
appliance complies with ANSI Z21.88.
SELECTING LOCATION
In selecting a location, the following precau-
tions must be observed:
• Do not connect this appliance to a chimney
system used for solid fuel burning fireplace.
• Due to high temperatures, do not locate
this appliance in high traffic areas or near
furniture and draperies.