![FMC Ao4 Скачать руководство пользователя страница 26](http://html.mh-extra.com/html/fmc/ao4/ao4_operation-and-maintenance-manual_2312614026.webp)
Doc No: OMM50001254
Rev: A Page 26 of 47
Subject to contractual terms and conditions to the contrary, this document and all the information contained herein are the confidential and exclusive
property of FMC Technologies, and may not be reproduced, disclosed, or made public in any manner prior to express written authorization by FMC.
9.1
Replacing Cup Pistons
1. Bleed off all pressure and ensure the pump power supply is off and is
disconnected (Locked and Tagged out, if applicable).
2. Remove the fluid cylinder (38) from
pump by removing the three cap
screws (39) holding it to the power
frame, then lift the fluid cylinder off
the top of the ceramic cylinders
(42).
3. Remove the ring seals (41) and o-
rings (40) from the top of the
cylinders or from the counter bores
of the fluid cylinder.
4. Remove the cap screw (44) and
piston cup washer (45) from each
of the two cylinders.
5. Lift the ceramic cylinder (42) off the
top of the power frame (1). Friction
will usually keep the piston cup (46)
inside the cylinder as it is removed.
Once the cylinders and pistons are
off the pump, take them to a bench
and press them out from the top.
6. Remove the piston holder (47) and
o-ring (48) from the crosshead shaft
(6).