Doc No: OMM50001254
Rev: A Page 15 of 47
Subject to contractual terms and conditions to the contrary, this document and all the information contained herein are the confidential and exclusive
property of FMC Technologies, and may not be reproduced, disclosed, or made public in any manner prior to express written authorization by FMC.
6. Check to ensure that power is locked out and tagged out. Turn the pump over by
hand if possible to ensure free, unobstructed operation.
7. Make sure that all guards are in place and secure. Verify that all personnel are in
safe positions and that system conditions are acceptable for operation.
8. The pump is now ready to start. NOTICE: Whenever possible, use a bypass in the
discharge line to allow the pump to start in the unloaded condition (no discharge
and pressure). Slowly close the bypass line to bring the pump into full load
conditions. Shut down immediately if the flow becomes unsteady, pressure
fluctuates, or if unusual sounds or vibrations are noted.
9. Take temperature readings of the power end and stuffing boxes. Do not exceed
170°F (77°C) on power end.