Doc No: OMM50001254
Rev: A Page 10 of 47
Subject to contractual terms and conditions to the contrary, this document and all the information contained herein are the confidential and exclusive
property of FMC Technologies, and may not be reproduced, disclosed, or made public in any manner prior to express written authorization by FMC.
cause equipment damage. Injury may result when starting equipment that has been
damaged.
Whenever the pump is stored or idle in conditions that are near or below freezing, any
water based fluids should be removed from the pump. The best way to do this is to run
the pump for a few seconds with the suction and discharge lines disconnected or open
to atmosphere. This will clear the majority of the fluid from the pumping chamber as
well as the suction and discharge manifolds. After the run, blow compressed air
through the fluid end to remove all traces of fluid.
As an alternative to the previous procedure, a compatible antifreeze solution can be
circulated through the fluid end. RV antifreeze, propylene glycol, is recommended for
this purpose. Remember that any fluid that poses an environmental hazard or is toxic
must be handled and disposed of properly.
3.0
Installation Guidelines
A proper installation is essential to optimal performance, long service life, and reduced
maintenance requirements. Take time to thoroughly plan all aspects of your installation.
3.1
General Location
It is important to position the pump on as flat and level a surface as possible to assist
the splash oil lubrication system. Park mobile equipment, such as sewer cleaner trucks
or drilling machines, on as level a surface as possible. Locate the pump as close to the
suction source as possible to allow for the shortest and most direct routing of the inlet
piping.
3.2
Mounting Pump to Foundation and Power Source
For units that are V-belt driven, check the alignment of the sheaves after the unit is
installed on its permanent mounting. Tighten belts to the proper tension as
recommended by the belt manufacturer. Verify that the sheaves are in line and parallel
to each other with a straight edge.
CAUTION
Never operate the pump without the belt guard securely installed.