FM4040 Installation Instructions

                                            

                                                                                              

CI 202 Iss 1        26-11-02                       Page 8 of 20

Once the Sounders and dialler have been connected and the installation
completed a full test with remote signalling should be carried out.

HOW TO MAKE A PROGRAMMING CHANGE

The following sequence shows how to change a program option:

1. 

 Enter the engineers code 4 6 7 9

The Alarm led will flash slowly  to indicate that you are in the program mode.

2.  

Key in the two digit program number.

(The zone led's indicate which option is set.)

3.  

Key in the option required

(The zone led's indicate your choice)

4.  

Press the Full Set key   to exit that program step.

5.

 When finished with programming key in 48 to exit engineer mode.

ERROR CORRECTION VIA THE PART SET KEY

If you accidentally enter an engineer program number and change an option
value, you can undo the change by pressing the Part Set key before exiting the
program step via the Full Set key.

EXAMPLE:    

 To make supervision active.

Key in     4 6 7 9 

  

To enter engineer program mode

Key in 40    To select supervision 

Key in  1

 

    To make supervisory active.

                   Zone 1 LED indicates your choice

Press the Full Set button to exit the program step.

Note:

 The Full set button must be pressed to complete each program step.

Until the Full Set button is pressed any key press just changes your choice of
option.

Содержание FM4040

Страница 1: ...s 1 26 11 02 Page 1 of 20 FM4040 CLASS 6 INTERFACE INSTALLATION INSTRUCTIONS FM Electronics Ltd The market leader in high security wireless alarm systems Zones 1 8 Panic Fire Full set Part set Off Sig...

Страница 2: ...LATION 6 HOW TO MAKE A PROGRAMMING CHANGE 8 ADDING WIRELESS DEVICES 9 PROGRAMMING SYSTEM OPTIONS 11 PROGRAMMING RESTORE FACTORY DEFAULTS 11 PROGRAMMING ENGINEER FUNCTIONS TESTS 12 PROGRAMMING INVERTIN...

Страница 3: ...et Currently Part or Full Set inputs both function in the same way When an Armed voltage from the main control panel is connected to one of these terminals the FM4040 knows when the main control is ar...

Страница 4: ...FM4040 Installation Instructions CI 202 Iss 1 26 11 02 Page 4 of 20 INTERFACE CONNECTIONS...

Страница 5: ...80 wireless keypad The polarity is 12v going to 0v when armed They can be inverted with Program option 65 Fault outputs These voltage outputs are for connection to a communicator Supervisory operates...

Страница 6: ...se radio reflections which oppose the signal being received from the detector with a resultant reduction in the received signal strength Metalwork close by can result in complete cancellation therefor...

Страница 7: ...o will remain stored even in the event of complete power failure 9 Radio test using the RSSI output To measure the signal strength received from a detector i Connect a Voltmeter to the RSSI output ter...

Страница 8: ...e your choice 4 Press the Full Set key to exit that program step 5 When finished with programming key in 48 to exit engineer mode ERROR CORRECTION VIA THE PART SET KEY If you accidentally enter an eng...

Страница 9: ...r To add a detector to a zone briefly short out the learn jumper on the detector and ensure that the learn pins are not left permanently shorted The PIR sends a learn by pressing the walk test button...

Страница 10: ...d zone 1 LED will indicate that one sensor has been programmed in Up to eight sensors can be programmed onto the fire zone by simply shorting out the learn jumper of each one in turn Press the Full Se...

Страница 11: ...your detectors are 4600 series Do not select supervisory if using zoned Panic buttons 1 Supervision O No supervision Press the full set key to exit PROGRAMMING RESTORE FACTORY DEFAULTS 44 RESTORE ENT...

Страница 12: ...git code twice 48 LEAVE ENGINEER MODE If any devices have their tampers open the display shows which zones are tampered and will generate an error beep The tampers must be restored before leaving engi...

Страница 13: ...FM4040 Installation Instructions CI 202 Iss 1 26 11 02 Page 13 of 20 Key 6 Part set Key 7 Full set Key 8 Jamming Press the full set key to exit...

Страница 14: ...be set to be energised all the time Key 1 changes zone 1 Key 2 changes zone 2 Key 3 changes zone 3 Key 4 changes zone 4 Key 5 changes zone 5 Key 6 changes zone 6 Key 7 changes zone 7 Key 8 changes zo...

Страница 15: ...ormally de energised Key 5 changes Fire relay Z5 LED on relay normally energised Off relay normally de energised Key 6 changes Part set output Z6 LED on ve removed Off ve applied Key 7 changes Full se...

Страница 16: ...hange until you have keyed in the same 4 digit PIN number twice If no key is pressed for 20 seconds the program mode is aborted and the panel will revert to the original pin number CHIME OPTION If you...

Страница 17: ...detector is triggered a chime tone will be generated On return to the panel the zone indicators will be illuminated indicating which zones have been triggered Pressing the Off 0 key will clear the ind...

Страница 18: ...n Full Set 0 All the time 1 Only when Part or Full set input is high Press the full set key to exit 62 FAULT OUTPUTS ALSO OPERATE THE ZONE OUTPUT Default is 0 If set to 1 the zone and fault outputs op...

Страница 19: ...of 20 78 Zone 8 operation time Key 1 NORMAL the relay follows the detector Default Key 2 Latch whilst Armed input is present Key 3 Momentary 2 seconds Key 4 Momentary 10 seconds Key 5 Momentary 30 sec...

Страница 20: ...k if it has been programmed onto the correct zone Note the panel will not allow you to program a detector onto two zones When programmed onto a zone any previous zone allocation will be deleted PIR NO...

Отзывы: