PROGRAMMING –ENGINEER FUNCTIONS & TESTS
45 AUDIBLE RECEIVE MODE
The output from the receiver can be heard on the panel loudspeaker.
Press the full set key to exit.
46 DISPLAY ENGINEERS LOG
Press keys 1 to 8 to view the last 8 events.
Most recent is displayed on key 1.
Key 9 shows the last "First to Alarm" (Last FTA)
Press the full set key to exit.
47 CHANGE ENGINEERS ACCESS CODE
Key in a 4 digit code twice.
48 LEAVE ENGINEER MODE
If any devices have their tampers open, the display shows which zones are
tampered and will generate an error beep.
The tampers must be restored before leaving engineer mode by pressing 48
again.
66 TEST ZONES 1-8
Zone 1 to 8 relays can be operated for test purposes. When you exit from this
mode the relays will always revert back to normal.
Keys 1 to 8 toggle zone relays 1 to 8
Press the full set key to exit
67 TEST THE OTHER 8 OUTPUTS
The other outputs can be tested . When you exit from this mode the outputs will
always revert back to normal.
Key 1 = Tamper
Key 2 = Low battery
Key 3 = Supervisory
Key 4 = Panic
Key 5 = Fire