FM4040 Installation Instructions
CI 202 Iss 1 26-11-02 Page 11 of 20
PROGRAMMING – SYSTEM OPTIONS
27 P.A. SILENT / AUDIBLE
The factory default is silent.
1= Silent*
O= Audible
Press the full set key to exit.
40
SUPERVISORY
Do not select supervisory unless all your detectors are 4600 series.
Do not select supervisory if using zoned Panic buttons.
1= Supervision
O= No supervision*
Press the full set key to exit.
PROGRAMMING – RESTORE FACTORY DEFAULTS
44 RESTORE ENTIRE NV RAM TO FACTORY DEFAULT VALUES
Short out the MEM link while keying in 44.
All zone LED's will come on, the panel will emit a long bleep and will go out of
engineering mode into the day state.
WARNING:
This will delete all detectors from the system.