![FM Electronics FM4040 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/fm-electronics/fm4040/fm4040_installation-instructions-manual_2312500010.webp)
FM4040 Installation Instructions
CI 202 Iss 1 26-11-02 Page 10 of 20
You can add up to 8 PA's to the panic zone by simply pressing each one in turn.
Press the Full Set key to exit.
10
FIRE ALARM SENSORS
To delete all Fire sensors press Part & 0 keys together.
To add a fire sensor, short out the learn jumper.
The panel will emit 2 short blips to indicate that it has read the sensor and zone 1
LED will indicate that one sensor has been programmed in.
Up to eight sensors can be programmed onto the fire zone by simply shorting out
the learn jumper of each one in turn.
Press the Full Set key to exit
11
REMOTE CONTROLS
To delete all Remote Controls press Part & 0 keys together.
To add a remote control transmit a Panic. The panel will emit 2 short blips to
indicate that it has read the remote control and LED 1 will indicate that one
remote has been programmed in.
You can add up to 8 remote controls by simply pressing each one in turn.
Press the Full Set key to exit.