![FM Electronics FM4040 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/fm-electronics/fm4040/fm4040_installation-instructions-manual_2312500003.webp)
FM4040 Installation Instructions
CI 202 Iss 1 26-11-02 Page 3 of 20
MAIN PCB CONNECTIONS
4-5
Tamper -ve return. This terminal must be connected to -ve Aux.
12.
Part Set hard wired arming input. Apply +12v to arm. Remove to unset.
13.
Full Set hard wired arming input. Apply +12v to arm. Remove to unset.
Currently Part or Full Set inputs both function in the same way.
When an Armed voltage from the main control panel is connected to one of these
terminals, the FM4040 knows when the main control is armed. Once armed any
activation from a wireless detector will be stored in the engineers log.
RECEIVED SIGNAL STRENGTH INDICATION (RSSI)
For connection to a digital voltmeter to indicate the Signal Strength of a
transmission received from a detector. (Refer to section on using the RSSI
output).