APPENDIX C     FAULT FINDING GUIDE

ZONE LED FLASHING

  

Flashing with tamper LED. (A detector has an open tamper).
Flashing with Battery LED. (The detectors battery needs replacing).

SIGNALLING LED ON  

    The system is being blocked by a continuous

transmission.

SIGNALLING LED FLASHING

Flashing together with a zone indicator. The

system is set as a supervised system and the detector indicated by the flashing
zone LED has failed to report in. ( Re-site the detector where there is good radio
reception.  Use the RSSI output to check.

CONTACT TRANSMITTER  NOT WORKING 

  Check the magnetic contact is

operating correctly.   Open lid and check what zone it should be on.  Go into the
panel engineer mode and check if it has been programmed onto the correct zone.
Note: the panel will not allow you to program a detector onto two zones. When
programmed onto a zone any previous zone allocation will be deleted.

PIR NOT WORKING   

 The detector needs 6 minutes to settle on power up.

Set the control into operator walk test mode and walk test the detector.  Pressing
the walk test button puts the PIR into walk test mode & overrides the 2 minute
inhibit timer.

CUSTOMER HAS FORGOTTEN THEIR CODE

Open the panel and short

out the MEM jumper.  The user and engineer codes will be restored to the factory
defaults 1234 & 4679.  No other programming is affected.

THE SYSTEM IS NOT FUNCTIONING AS PROGRAMMED

Check all program options & correct any errors.
If not satisfied, perform a full Factory default restore as described on page 12. &
re-program everything.

FM Electronics Ltd

.

12-14 Forest Vale Road, Cinderford, GLOS. GL14 2PH

Tel. 01594 827070   Fax. 01594 827066

Email  [email protected]

Содержание FM4040

Страница 1: ...s 1 26 11 02 Page 1 of 20 FM4040 CLASS 6 INTERFACE INSTALLATION INSTRUCTIONS FM Electronics Ltd The market leader in high security wireless alarm systems Zones 1 8 Panic Fire Full set Part set Off Sig...

Страница 2: ...LATION 6 HOW TO MAKE A PROGRAMMING CHANGE 8 ADDING WIRELESS DEVICES 9 PROGRAMMING SYSTEM OPTIONS 11 PROGRAMMING RESTORE FACTORY DEFAULTS 11 PROGRAMMING ENGINEER FUNCTIONS TESTS 12 PROGRAMMING INVERTIN...

Страница 3: ...et Currently Part or Full Set inputs both function in the same way When an Armed voltage from the main control panel is connected to one of these terminals the FM4040 knows when the main control is ar...

Страница 4: ...FM4040 Installation Instructions CI 202 Iss 1 26 11 02 Page 4 of 20 INTERFACE CONNECTIONS...

Страница 5: ...80 wireless keypad The polarity is 12v going to 0v when armed They can be inverted with Program option 65 Fault outputs These voltage outputs are for connection to a communicator Supervisory operates...

Страница 6: ...se radio reflections which oppose the signal being received from the detector with a resultant reduction in the received signal strength Metalwork close by can result in complete cancellation therefor...

Страница 7: ...o will remain stored even in the event of complete power failure 9 Radio test using the RSSI output To measure the signal strength received from a detector i Connect a Voltmeter to the RSSI output ter...

Страница 8: ...e your choice 4 Press the Full Set key to exit that program step 5 When finished with programming key in 48 to exit engineer mode ERROR CORRECTION VIA THE PART SET KEY If you accidentally enter an eng...

Страница 9: ...r To add a detector to a zone briefly short out the learn jumper on the detector and ensure that the learn pins are not left permanently shorted The PIR sends a learn by pressing the walk test button...

Страница 10: ...d zone 1 LED will indicate that one sensor has been programmed in Up to eight sensors can be programmed onto the fire zone by simply shorting out the learn jumper of each one in turn Press the Full Se...

Страница 11: ...your detectors are 4600 series Do not select supervisory if using zoned Panic buttons 1 Supervision O No supervision Press the full set key to exit PROGRAMMING RESTORE FACTORY DEFAULTS 44 RESTORE ENT...

Страница 12: ...git code twice 48 LEAVE ENGINEER MODE If any devices have their tampers open the display shows which zones are tampered and will generate an error beep The tampers must be restored before leaving engi...

Страница 13: ...FM4040 Installation Instructions CI 202 Iss 1 26 11 02 Page 13 of 20 Key 6 Part set Key 7 Full set Key 8 Jamming Press the full set key to exit...

Страница 14: ...be set to be energised all the time Key 1 changes zone 1 Key 2 changes zone 2 Key 3 changes zone 3 Key 4 changes zone 4 Key 5 changes zone 5 Key 6 changes zone 6 Key 7 changes zone 7 Key 8 changes zo...

Страница 15: ...ormally de energised Key 5 changes Fire relay Z5 LED on relay normally energised Off relay normally de energised Key 6 changes Part set output Z6 LED on ve removed Off ve applied Key 7 changes Full se...

Страница 16: ...hange until you have keyed in the same 4 digit PIN number twice If no key is pressed for 20 seconds the program mode is aborted and the panel will revert to the original pin number CHIME OPTION If you...

Страница 17: ...detector is triggered a chime tone will be generated On return to the panel the zone indicators will be illuminated indicating which zones have been triggered Pressing the Off 0 key will clear the ind...

Страница 18: ...n Full Set 0 All the time 1 Only when Part or Full set input is high Press the full set key to exit 62 FAULT OUTPUTS ALSO OPERATE THE ZONE OUTPUT Default is 0 If set to 1 the zone and fault outputs op...

Страница 19: ...of 20 78 Zone 8 operation time Key 1 NORMAL the relay follows the detector Default Key 2 Latch whilst Armed input is present Key 3 Momentary 2 seconds Key 4 Momentary 10 seconds Key 5 Momentary 30 sec...

Страница 20: ...k if it has been programmed onto the correct zone Note the panel will not allow you to program a detector onto two zones When programmed onto a zone any previous zone allocation will be deleted PIR NO...

Отзывы: