![FM Electronics FM4040 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/fm-electronics/fm4040/fm4040_installation-instructions-manual_2312500020.webp)
FM4040 Installation Instructions
CI 202 Iss 1 26-11-02 Page 20 of 20
APPENDIX C FAULT FINDING GUIDE
ZONE LED FLASHING
Flashing with tamper LED. (A detector has an open tamper).
Flashing with Battery LED. (The detectors battery needs replacing).
SIGNALLING LED ON
The system is being blocked by a continuous
transmission.
SIGNALLING LED FLASHING
Flashing together with a zone indicator. The
system is set as a supervised system and the detector indicated by the flashing
zone LED has failed to report in. ( Re-site the detector where there is good radio
reception. Use the RSSI output to check.
CONTACT TRANSMITTER NOT WORKING
Check the magnetic contact is
operating correctly. Open lid and check what zone it should be on. Go into the
panel engineer mode and check if it has been programmed onto the correct zone.
Note: the panel will not allow you to program a detector onto two zones. When
programmed onto a zone any previous zone allocation will be deleted.
PIR NOT WORKING
The detector needs 6 minutes to settle on power up.
Set the control into operator walk test mode and walk test the detector. Pressing
the walk test button puts the PIR into walk test mode & overrides the 2 minute
inhibit timer.
CUSTOMER HAS FORGOTTEN THEIR CODE
Open the panel and short
out the MEM jumper. The user and engineer codes will be restored to the factory
defaults 1234 & 4679. No other programming is affected.
THE SYSTEM IS NOT FUNCTIONING AS PROGRAMMED
Check all program options & correct any errors.
If not satisfied, perform a full Factory default restore as described on page 12. &
re-program everything.
FM Electronics Ltd
.
12-14 Forest Vale Road, Cinderford, GLOS. GL14 2PH
Tel. 01594 827070 Fax. 01594 827066
Email [email protected]