123B/124B/125B
Users Manual
Max. Input Voltage A and B
direct, with test leads, or with VP41 Probe ......... 600 Vrms Cat IV, 750 Vrms maximum voltage.
with BB120.......................................................... 600 Vrms
(For detailed specifications, see
Safety
, Figure 15 and Figure 16.)
Max. Floating Voltage, from any
terminal to ground
................................................ 600 Vrms Cat IV, 750 Vrms up to 400 Hz
Vertical Accuracy
..................................................
±
(1 % + 0.05 range/div)
Max. Vertical Move
................................................
±
5 divisions
Horizontal
Scope Modes
......................................................... Normal, Single, Roll
Ranges
Normal:
Equivalent sampling
125B, 124B ................................................. 10 ns to 500 ns/div
123B............................................................ 20 ns to 500 ns/div
Real time sampling ......................................... 1
μ
s to 5 s/div
Single (real time) ............................................. 1
μ
s to 5 s/div
Roll (real time) ................................................. 1s to 60 s/div
Sampling Rate (for both channels simultaneously)
Equivalent sampling (repetitive signals) .............. up to 4 GS/s
Real time sampling
1
μ
s to 60 s/div ................................................ 40 MS/s
Time Base Accuracy
Equivalent sampling ............................................
±
(0.4 % + 0.025 time/div)
Real time sampling .............................................
±
(0.1 % + 0.025 time/div)
Glitch Detection
....................................................
≥
25 ns @ 20 ns to 60 s/div
Horizontal Move
.................................................... 12 divisions, trigger point can be positioned anywhere across the screen
70
Содержание ScopeMeter 123B
Страница 8: ...123B 124B 125B U ivatelsk p ru ka vi...
Страница 10: ...123B 124B 125B U ivatelsk p ru ka viii...
Страница 104: ...123B 124B 125B Users Manual vi...
Страница 106: ...123B 124B 125B Users Manual viii...
Страница 123: ...4 Industrial ScopeMeter Scope and Meter Mode A B 5 A B hxv04 eps Figure 8 Correct Grounding Setup 17...
Страница 124: ...6 7 123B 124B 125B Users Manual A B 10 mV A 1 mV A hxv57 eps Figure 9 Temperature and Current Measurement Setup 18...