Live Move screen
Note
If Static measurement mode is selected, the Live Move screen is accessed only after the
desired 45° clock position
(1)
of the sensor and laser has been selected and confirmed
by tapping
in the position selection screen that appears.
Live Move is monitored in both horizontal (H) and vertical (V) planes simultaneously.
l
(1)
Tap the 'V/H' icon to follow both vertical and horizontal foot corrections sim-
ultaneously
l
(2)
Tap the 'V' icon to follow the vertical foot corrections
l
(3)
Tap the 'H' icon to follow the horizontal foot corrections
l
(4)
Arrows indicate direction and magnitude to move machine feet
l
(5)
Tolerance coded gap and offset coupling values
l
(6)
Tapping the 'Undo' icon allows user to re-measure or start Live Move afresh
l
(7)
Tapping the 'Proceed' icon allows user to re-measure or start Live Move afresh
Once Live Move has been detected, the 'Cancel' icon
replaces the 'Undo' icon
.
ROTALIGN touch EX
75
On-board help
Содержание PRUFTECHNIK ROTALIGN touchEX
Страница 1: ...ROTALIGN touch EX On board help ...
Страница 2: ...ROTALIGN touch EX On board help Version 2 3 Edition 03 2020 Part No DOC 52 202 EN ...
Страница 11: ...This page intentionally left blank ...
Страница 13: ...12 Version 2 3 On board help ...
Страница 19: ...Information on the sensor and laser may be found in the related topic below 18 Version 2 3 On board help ...
Страница 43: ...42 Version 2 3 On board help ...
Страница 87: ...Note If no template is selected all template list options are unavailable 86 Version 2 3 On board help ...
Страница 137: ...136 Version 2 3 On board help ...
Страница 161: ...This page intentionally left blank ...