Soft foot
Soft foot measurement can be started from any screen where the 'Soft foot' icon [
] is act-
ive. Tap
to start soft foot measurement. The values may be determined by sensor meas-
urement or entered manually from values established using manual methods such as feeler
gauges and shims.
Sensor measurement
Activate sensor measurement by swiping the green button
(1)
to "Sensor". The laser beam
must have the status "Laser centered" or "Laser OK". Refer to laser beam adjustment.
Tap any one of the four pulsating value fields to start soft foot measurement at the respective
machine foot.
Loosen the corresponding foot bolt (see hint
1
). The recorded soft foot value is displayed [
2
].
When the soft foot value stabilizes, tap
the 'Proceed' icon or recorded value
(2)
, then
tighten the bolt (see hint
1
). If desired, the soft foot measurement at the corresponding foot is
canceled by tapping
the 'Cancel' icon. The above soft foot measurement procedure is
repeated for all four feet positions.
102
Version:2.3
On-board help
Содержание PRUFTECHNIK ROTALIGN touchEX
Страница 1: ...ROTALIGN touch EX On board help ...
Страница 2: ...ROTALIGN touch EX On board help Version 2 3 Edition 03 2020 Part No DOC 52 202 EN ...
Страница 11: ...This page intentionally left blank ...
Страница 13: ...12 Version 2 3 On board help ...
Страница 19: ...Information on the sensor and laser may be found in the related topic below 18 Version 2 3 On board help ...
Страница 43: ...42 Version 2 3 On board help ...
Страница 87: ...Note If no template is selected all template list options are unavailable 86 Version 2 3 On board help ...
Страница 137: ...136 Version 2 3 On board help ...
Страница 161: ...This page intentionally left blank ...