l
Clamp the sensor onto the support posts by tightening the yellow knobs.
l
Connect the sensor to the RF module using the RF module cable.
The shorter 90-degree connector of the RF module cable is connected to the 8-pin sensor
socket. The keyway orientation should be noted, and the knurled sleeve of the connector
screwed in until it is snug. The longer 90-degree connector of the RF module cable is
inserted into the four-pin socket on the side of the RF module with a groove, matching
the red dot on the plug to the groove on the socket to ensure proper plug orientation.
ROTALIGN touch EX
25
On-board help