![Fluke Calibration RUSKA 7615 Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/fluke-calibration/ruska-7615/ruska-7615_user-manual_2310769044.webp)
RUSKA 7615
Users Manual
5-4
ANSI/IEEE 488.2-1987 Command Summary
*CLS
Clear
Status
*ESE?
Event
Status
Enable
Query
*ESE <number>
Event
Status
Enable
*ESR?
Event
Status
Register
*IDN?
Identification
*OPC?
Operation Complete Query (Returns 1)
*OPC
Operation
Complete
*RST
Reset
*SRE?
Service
Request
Enable
Query
*SRE <number>
Service Request Enable
*STB?
Status
Byte
Query
*TST?
Self-Test
Query
*WAI
Wait
(No
operation)
SCPI Command Summary
The current value associated with a SCPI command may be read by appending a question
mark to the command. For example CALC:LIM:UPP? will return the current upper
pressure limit.
MEASure
[:PRESsure]?
returns
current
pressure
reading
:PRESsure2?
return
pump
pressure
:POSITION?
returns
pump
position
(%)
CALCulate
:LIMit
:LOWer
<number> get/set
low
pressure
limit
:SLEW
<number> get/set
slew
rate
limit
:UPPer
<number> get/set
high
pressure
limit
:VENT
<number>
get/set
auto-vent
limit
:TARE
:VALue
<number> get/set
tare
value
:STATe ON/OFF
set tare using current pressure
CALibration
[:PRESsure]
:DATA
:POINts? read
number
of
calibration
constants
:VALue<n>?
read
label,
calibration
constant
:CALibration
:POINts? read
number
of
calibration
points
:VALue<n>?
read
nominal
calibration
point
:VALue<n>
<number>
perform
calibration
point
:ZERO
performs
zero
calibration
:VALUE
<number> sets
vacuum
value
:INITiate
enter
zero
calibration
mode
:INITiate?
returns status for cal, press, temp,
ref
:RUN
start
zero
calibration
:STOP
abort
zero
calibration
:PRESsure2
:DATA <number>,<number>
sets C0, C1 for pump pressure
:VALue
<number> sets
first
calibration
point
:VALue2 <number>
sets second calibration point
:POSition
:DATA <number>, <number>
sets C0, C1 position
:DATA?
reads
C0,
C1
:VALue
<number> sets
second
calibration
point
:MODE?
calibration
edit
enabled?
:MODE ON¦OFF¦1¦0
enable calibration edit
(Cal.
button
required)
DISP
:ENABle ON¦OFF¦1¦0
turns front panel display on/off
:TEXT <string>
displays message on front panel
:BGRaph <number>
sets bar graph maximum
OUTPut
:STATe
ON¦OFF¦1¦0
off=MEASure,
on=CONTrol
:STATe?
returns
0=Measure
or
1=Control
Содержание RUSKA 7615
Страница 8: ...RUSKA 7615 Users Manual vi...
Страница 10: ...RUSKA 7615 Users Manual viii...
Страница 16: ...RUSKA 7615 Users Manual 1 6...
Страница 22: ...RUSKA 7615 Users Manual 2 6...
Страница 40: ...RUSKA 7615 Users Manual 4 12...
Страница 48: ...RUSKA 7615 Users Manual 5 8...
Страница 62: ...RUSKA 7615 Users Manual A 4...